Carbon Steel Boiler and Heat Exchanger Tubes

Seamless carbon steel tubes to ASTM A179 for heat exchangers and condensers, A192 for high-pressure boilers and A210 for boiler and superheater tubes, with EN 10216-2, BS 3059, JIS G3461 and GB/T 3087 and 5310 equivalents. Made to ASTM A179 / ASME SA-179, ASTM A192 / SA-192, ASTM A210 / SA-210. Supplied from Dubai with an Indus part number for each size and mill test certificates on request.
Key features
- Product type: Carbon Steel Boiler and Heat Exchanger Tubes
- Construction: Seamless, cold drawn or hot finished
- Standards: ASTM A179 / ASME SA-179, ASTM A192 / SA-192, ASTM A210 / SA-210, ASTM A450, ASTM A1016, EN 10216-2, DIN 17175 (superseded by EN 10216-2), GB/T 3087-2008, BS 3059-1/-2, JIS G3461
- Base tube material: A179; A192; A210 A-1/C; P235GH; P265GH; St35.8; St45.8; GB/T 3087 10/20
- Outside diameter: 15.88–50.8 mm
- Wall thickness: 1.24–3.4 mm
- Product type
- Carbon Steel Boiler and Heat Exchanger Tubes
- Construction
- Seamless, cold drawn or hot finished
- Base tube material
- A179; A192; A210 A-1/C; P235GH; P265GH; St35.8; St45.8; GB/T 3087 10/20
Product description
Seamless carbon steel tubes to ASTM A179 for heat exchangers and condensers, A192 for high-pressure boilers and A210 for boiler and superheater tubes, with EN 10216-2, BS 3059, JIS G3461 and GB/T 3087 and 5310 equivalents. Ordered by OD and minimum wall, the wall usually given as a BWG gauge.
Specification
- ASTM A179 size scope: OD 3.2–76.2 mm (1/8–3 in); seamless, cold drawn
- ASTM A179 max hardness: 72 HRB
- ASTM A192 max hardness: 137 HB (wall ≥5.1 mm) / 77 HRB
- ASTM A210 max hardness: A-1: 79 HRB / 143 HB; C: 89 HRB / 179 HB
- Common heat-exchanger tube ODs: 15.88, 19.05, 25.40, 31.75, 38.10, 50.80 mm (5/8, 3/4, 1, 1-1/4, 1-1/2, 2 in)
- Cold-drawn minimum-wall tube range: 12.70×0.89 to 76.20×5.59 mm (0.500×0.035 to 3.000×0.220 in, 20–5 BWG)
- GB/T 3087 general length: 4–12.5 m
- TEMA gauges: TEMA's tube gauge table is informative; wall may be set by ASME VIII calculation
- Equivalent grades (indicative): P235GH ≈ St35.8 ≈ A192 / A106 A ≈ BS 3059-1 320 / 3059-2 360 ≈ STB340; P265GH ≈ St45.8 ≈ A210 A-1 / A106 B ≈ STB410; A210 C / A106 C ≈ 17Mn4 (indicative — check each tender)
- Max service temperature, P235GH/P265GH class: about 450–500 °C indicative, depending on test category
- OD tolerance, cold-finished seamless and welded tube (mm): <25.4: ±0.10; 25.4–38.1: ±0.15; >38.1–<50.8: ±0.20; 50.8–<63.5: ±0.25; 63.5–<76.2: ±0.30; 76.2–101.6: ±0.38
- Wall tolerance, cold-finished minimum-wall tube: 0/+20% for OD ≤38.1 mm; 0/+22% for OD >38.1 mm
- Wall tolerance, hot-finished minimum-wall tube: ≤2.4 mm: 0/+40%; 2.4–3.8: 0/+35%; 3.8–4.6: 0/+33%; >4.6: 0/+28%
- Hydrostatic test pressure: P = 32000·t/D psi (220.6·t/D MPa), capped by A450 Table 7 (highest cap 4500 psi / 31 MPa)
Standards
ASTM A179 / ASME SA-179, ASTM A192 / SA-192, ASTM A210 / SA-210, ASTM A450, ASTM A1016, EN 10216-2, DIN 17175 (superseded by EN 10216-2), GB/T 3087-2008, BS 3059-1/-2, JIS G3461, BS 3059. Equivalent grades across ASTM, EN, DIN, JIS and GB/T standards are indicative; we check them against each tender.
Materials
- Tube: A179; A192; A210 A-1/C; P235GH; P265GH; St35.8; St45.8; GB/T 3087 10/20
Testing and documents
- A179: flattening, flaring, flange, hardness and hydrostatic tests
- EN 10216-2: tensile, flattening or ring tests, leak tightness, NDT at TC2
- GB/T 3087: hydro at P = 2SR/D with R = 60% of ReL, or eddy current/MFL/UT instead
- Hydrostatic per A450 at P = 32000 t/D psi, or NDT at the maker's option
- Mill test certificate to EN 10204 3.1 on request; third-party inspection can be arranged against your inspection and test plan
Where it is used
- Base tube for finned air-cooler bundles
- Boiler, economizer and HRSG water-wall tubes in power and desalination plants (A192/A210)
- Shell-and-tube exchangers and condensers in refineries and gas plants (A179)
Sizes
40 sizes, each under its own Indus part number in the size table. These are the common sizes; others are made on request.
Ordering
Quote the Indus part number from the size table, or send the standard and grade, the outside diameter and wall (BWG or millimetres, minimum or average wall), the length and the quantity. We quote with the mill certificates and the inspection you need.
Identification
| Parameter | Value |
|---|---|
| Product type | Carbon Steel Boiler and Heat Exchanger Tubes |
| Construction | Seamless, cold drawn or hot finished |
Compliance
| Parameter | Value |
|---|---|
| Standards | ASTM A179 / ASME SA-179, ASTM A192 / SA-192, ASTM A210 / SA-210, ASTM A450, ASTM A1016, EN 10216-2, DIN 17175 (superseded by EN 10216-2), GB/T 3087-2008, BS 3059-1/-2, JIS G3461 |
Construction
| Parameter | Value |
|---|---|
| Base tube material | A179; A192; A210 A-1/C; P235GH; P265GH; St35.8; St45.8; GB/T 3087 10/20 |
Dimensions
| Parameter | Value |
|---|---|
| Outside diameter | 15.88–50.8 mm |
| Wall thickness | 1.24–3.4 mm |
| Length | Random or fixed lengths; cut to length on request |
| Size table | Common sizes |
Quality
| Parameter | Value |
|---|---|
| Testing | A179: flattening, flaring, flange, hardness and hydrostatic tests; EN 10216-2: tensile, flattening or ring tests, leak tightness, NDT at TC2; GB/T 3087: hydro at P = 2SR/D with R = 60% of ReL, or eddy current/MFL/UT instead; Hydrostatic per A450 at P = 32000 t/D psi, or NDT at the maker's option |
| Certification | Mill test certificate to EN 10204 3.1 on request; third-party inspection by arrangement |
Application
| Parameter | Value |
|---|---|
| Typical services | Base tube for finned air-cooler bundles; Boiler, economizer and HRSG water-wall tubes in power and desalination plants (A192/A210); Shell-and-tube exchangers and condensers in refineries and gas plants (A179) |
Shipping & lead time
Sizes & part numbers
40 sizes- Indus part no.IH-TF-CB-CS-0159-124
- O.D. (mm)
- 15.88
- O.D. (in)
- 5/8
- BWG
- 18
- Min. wall (mm)
- 1.24
- Min. wall (in)
- 0.049
- Indus part no.IH-TF-CB-CS-0159-165
- O.D. (mm)
- 15.88
- O.D. (in)
- 5/8
- BWG
- 16
- Min. wall (mm)
- 1.65
- Min. wall (in)
- 0.065
- Indus part no.IH-TF-CB-CS-0159-211
- O.D. (mm)
- 15.88
- O.D. (in)
- 5/8
- BWG
- 14
- Min. wall (mm)
- 2.11
- Min. wall (in)
- 0.083
- Indus part no.IH-TF-CB-CS-0159-241
- O.D. (mm)
- 15.88
- O.D. (in)
- 5/8
- BWG
- 13
- Min. wall (mm)
- 2.41
- Min. wall (in)
- 0.095
- Indus part no.IH-TF-CB-CS-0159-277
- O.D. (mm)
- 15.88
- O.D. (in)
- 5/8
- BWG
- 12
- Min. wall (mm)
- 2.77
- Min. wall (in)
- 0.109
- Indus part no.IH-TF-CB-CS-0190-124
- O.D. (mm)
- 19.05
- O.D. (in)
- 3/4
- BWG
- 18
- Min. wall (mm)
- 1.24
- Min. wall (in)
- 0.049
- Indus part no.IH-TF-CB-CS-0190-165
- O.D. (mm)
- 19.05
- O.D. (in)
- 3/4
- BWG
- 16
- Min. wall (mm)
- 1.65
- Min. wall (in)
- 0.065
- Indus part no.IH-TF-CB-CS-0190-211
- O.D. (mm)
- 19.05
- O.D. (in)
- 3/4
- BWG
- 14
- Min. wall (mm)
- 2.11
- Min. wall (in)
- 0.083
Show all 40 sizesShow fewer sizes
- Indus part no.IH-TF-CB-CS-0190-241
- O.D. (mm)
- 19.05
- O.D. (in)
- 3/4
- BWG
- 13
- Min. wall (mm)
- 2.41
- Min. wall (in)
- 0.095
- Indus part no.IH-TF-CB-CS-0190-277
- O.D. (mm)
- 19.05
- O.D. (in)
- 3/4
- BWG
- 12
- Min. wall (mm)
- 2.77
- Min. wall (in)
- 0.109
- Indus part no.IH-TF-CB-CS-0190-305
- O.D. (mm)
- 19.05
- O.D. (in)
- 3/4
- BWG
- 11
- Min. wall (mm)
- 3.05
- Min. wall (in)
- 0.120
- Indus part no.IH-TF-CB-CS-0190-340
- O.D. (mm)
- 19.05
- O.D. (in)
- 3/4
- BWG
- 10
- Min. wall (mm)
- 3.40
- Min. wall (in)
- 0.134
- Indus part no.IH-TF-CB-CS-0254-124
- O.D. (mm)
- 25.40
- O.D. (in)
- 1
- BWG
- 18
- Min. wall (mm)
- 1.24
- Min. wall (in)
- 0.049
- Indus part no.IH-TF-CB-CS-0254-165
- O.D. (mm)
- 25.40
- O.D. (in)
- 1
- BWG
- 16
- Min. wall (mm)
- 1.65
- Min. wall (in)
- 0.065
- Indus part no.IH-TF-CB-CS-0254-211
- O.D. (mm)
- 25.40
- O.D. (in)
- 1
- BWG
- 14
- Min. wall (mm)
- 2.11
- Min. wall (in)
- 0.083
- Indus part no.IH-TF-CB-CS-0254-241
- O.D. (mm)
- 25.40
- O.D. (in)
- 1
- BWG
- 13
- Min. wall (mm)
- 2.41
- Min. wall (in)
- 0.095
- Indus part no.IH-TF-CB-CS-0254-277
- O.D. (mm)
- 25.40
- O.D. (in)
- 1
- BWG
- 12
- Min. wall (mm)
- 2.77
- Min. wall (in)
- 0.109
- Indus part no.IH-TF-CB-CS-0254-305
- O.D. (mm)
- 25.40
- O.D. (in)
- 1
- BWG
- 11
- Min. wall (mm)
- 3.05
- Min. wall (in)
- 0.120
- Indus part no.IH-TF-CB-CS-0254-340
- O.D. (mm)
- 25.40
- O.D. (in)
- 1
- BWG
- 10
- Min. wall (mm)
- 3.40
- Min. wall (in)
- 0.134
- Indus part no.IH-TF-CB-CS-0318-124
- O.D. (mm)
- 31.75
- O.D. (in)
- 1-1/4
- BWG
- 18
- Min. wall (mm)
- 1.24
- Min. wall (in)
- 0.049
- Indus part no.IH-TF-CB-CS-0318-165
- O.D. (mm)
- 31.75
- O.D. (in)
- 1-1/4
- BWG
- 16
- Min. wall (mm)
- 1.65
- Min. wall (in)
- 0.065
- Indus part no.IH-TF-CB-CS-0318-211
- O.D. (mm)
- 31.75
- O.D. (in)
- 1-1/4
- BWG
- 14
- Min. wall (mm)
- 2.11
- Min. wall (in)
- 0.083
- Indus part no.IH-TF-CB-CS-0318-241
- O.D. (mm)
- 31.75
- O.D. (in)
- 1-1/4
- BWG
- 13
- Min. wall (mm)
- 2.41
- Min. wall (in)
- 0.095
- Indus part no.IH-TF-CB-CS-0318-277
- O.D. (mm)
- 31.75
- O.D. (in)
- 1-1/4
- BWG
- 12
- Min. wall (mm)
- 2.77
- Min. wall (in)
- 0.109
- Indus part no.IH-TF-CB-CS-0318-305
- O.D. (mm)
- 31.75
- O.D. (in)
- 1-1/4
- BWG
- 11
- Min. wall (mm)
- 3.05
- Min. wall (in)
- 0.120
- Indus part no.IH-TF-CB-CS-0318-340
- O.D. (mm)
- 31.75
- O.D. (in)
- 1-1/4
- BWG
- 10
- Min. wall (mm)
- 3.40
- Min. wall (in)
- 0.134
- Indus part no.IH-TF-CB-CS-0381-124
- O.D. (mm)
- 38.10
- O.D. (in)
- 1-1/2
- BWG
- 18
- Min. wall (mm)
- 1.24
- Min. wall (in)
- 0.049
- Indus part no.IH-TF-CB-CS-0381-165
- O.D. (mm)
- 38.10
- O.D. (in)
- 1-1/2
- BWG
- 16
- Min. wall (mm)
- 1.65
- Min. wall (in)
- 0.065
- Indus part no.IH-TF-CB-CS-0381-211
- O.D. (mm)
- 38.10
- O.D. (in)
- 1-1/2
- BWG
- 14
- Min. wall (mm)
- 2.11
- Min. wall (in)
- 0.083
- Indus part no.IH-TF-CB-CS-0381-241
- O.D. (mm)
- 38.10
- O.D. (in)
- 1-1/2
- BWG
- 13
- Min. wall (mm)
- 2.41
- Min. wall (in)
- 0.095
- Indus part no.IH-TF-CB-CS-0381-277
- O.D. (mm)
- 38.10
- O.D. (in)
- 1-1/2
- BWG
- 12
- Min. wall (mm)
- 2.77
- Min. wall (in)
- 0.109
- Indus part no.IH-TF-CB-CS-0381-305
- O.D. (mm)
- 38.10
- O.D. (in)
- 1-1/2
- BWG
- 11
- Min. wall (mm)
- 3.05
- Min. wall (in)
- 0.120
- Indus part no.IH-TF-CB-CS-0381-340
- O.D. (mm)
- 38.10
- O.D. (in)
- 1-1/2
- BWG
- 10
- Min. wall (mm)
- 3.40
- Min. wall (in)
- 0.134
- Indus part no.IH-TF-CB-CS-0508-124
- O.D. (mm)
- 50.80
- O.D. (in)
- 2
- BWG
- 18
- Min. wall (mm)
- 1.24
- Min. wall (in)
- 0.049
- Indus part no.IH-TF-CB-CS-0508-165
- O.D. (mm)
- 50.80
- O.D. (in)
- 2
- BWG
- 16
- Min. wall (mm)
- 1.65
- Min. wall (in)
- 0.065
- Indus part no.IH-TF-CB-CS-0508-211
- O.D. (mm)
- 50.80
- O.D. (in)
- 2
- BWG
- 14
- Min. wall (mm)
- 2.11
- Min. wall (in)
- 0.083
- Indus part no.IH-TF-CB-CS-0508-241
- O.D. (mm)
- 50.80
- O.D. (in)
- 2
- BWG
- 13
- Min. wall (mm)
- 2.41
- Min. wall (in)
- 0.095
- Indus part no.IH-TF-CB-CS-0508-277
- O.D. (mm)
- 50.80
- O.D. (in)
- 2
- BWG
- 12
- Min. wall (mm)
- 2.77
- Min. wall (in)
- 0.109
- Indus part no.IH-TF-CB-CS-0508-305
- O.D. (mm)
- 50.80
- O.D. (in)
- 2
- BWG
- 11
- Min. wall (mm)
- 3.05
- Min. wall (in)
- 0.120
- Indus part no.IH-TF-CB-CS-0508-340
- O.D. (mm)
- 50.80
- O.D. (in)
- 2
- BWG
- 10
- Min. wall (mm)
- 3.40
- Min. wall (in)
- 0.134
O.D. (mm) — Outside diameter of the tube or pipe in millimetres. O.D. (in) — The same outside diameter in inches, as the trade orders it. BWG — Birmingham Wire Gauge of the wall, the usual way heat-exchanger tube wall is ordered. Min. wall (mm) — Minimum wall thickness in millimetres. Min. wall (in) — The same minimum wall in inches.
These are typical sizes for the range, not a full mill list. Other diameters, walls, fin geometries and lengths are made to order: tell us the standard and grade, the O.D. and wall, and the length you need. Mill test certificates to EN 10204 3.1 are available on request.
What are Carbon Steel Boiler and Heat Exchanger Tubes used for?▾
How do I read an Indus part number for Carbon Steel Boiler and Heat Exchanger Tubes, such as IH-TF-CB-CS-0159-124?▾
What sizes do Carbon Steel Boiler and Heat Exchanger Tubes come in?▾
What do I need to send to order Carbon Steel Boiler and Heat Exchanger Tubes to the right size and grade?▾
How are Carbon Steel Boiler and Heat Exchanger Tubes hydrostatically tested?▾
What tests and certificates come with Carbon Steel Boiler and Heat Exchanger Tubes?▾
Which materials and grades are Carbon Steel Boiler and Heat Exchanger Tubes available in?▾
Which standards apply to Carbon Steel Boiler and Heat Exchanger Tubes?▾
What do Carbon Steel Boiler and Heat Exchanger Tubes connect to or fit with?▾
How should Carbon Steel Boiler and Heat Exchanger Tubes be inspected on receipt and stored?▾
How are Carbon Steel Boiler and Heat Exchanger Tubes shipped, and can they be exported from Dubai?▾
Do you keep Carbon Steel Boiler and Heat Exchanger Tubes in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this part
Heat-transfer tubes
A179 vs A192 vs A210 vs A213: choosing boiler and exchanger tube
Four ASTM standards cover most carbon and alloy steel tube in exchangers, boilers and superheaters. What each is for, how they differ in chemistry and strength, which tests they carry, and how to choose — with the grade tables.
3 min read
Heat-transfer tubes
From DIN 17175 and DIN 1629 to EN 10216: what replaced what
Old drawings still call up St35.8, St45.8, 15Mo3 and 13CrMo44 to DIN 17175, and St37.0 or St52.0 to DIN 1629. Those standards are withdrawn. Which EN 10216 grades replaced them, how close the match is, and how to order tube for an old drawing.
3 min read
Heat-transfer tubes
Reading a mill test certificate to EN 10204 3.1
Every length of pressure tube should be traceable to a certificate. What EN 10204 types 2.1, 2.2, 3.1 and 3.2 mean, what a 3.1 certificate for tube should contain, and the checks to make before the tube goes into a bundle.
3 min read