Bijur Delimon DC4, DC40, DC41 and DC42 Dualine Central Stations

Bijur Delimon DC4, DC40, DC41 and DC42 Dualine Central Stations: 26 part numbers, for Dualine systems; grease, oil; 200 LB, 100 LB, 30 GAL reservoirs. DC central stations are the pumping stations for Bijur Delimon (Farval) Dualine two-line grease and oil systems in heavy industry. From Indus Hydraulics, authorised Bijur Delimon distributor for the Middle East, supplied direct from the manufacturer.
Key features
- Product type: Electric lubrication pump
- Series: Bijur Delimon DC4, DC40, DC41 and DC42 Dualine Central Stations
- Drive: Electric motor
- Lubrication system: Dualine
- Lubricant: Grease, Oil
- Reservoir: 200 LB, 100 LB, 30 GAL
- Max pressure: 3,000 psi (207 bar)
- Supply voltage: 230/460VAC
- Product type
- Electric lubrication pump
- Drive
- Electric motor
- Lubrication system
- Dualine
- Lubricant
- Grease, Oil
Product description
DC central stations are the pumping stations for Bijur Delimon (Farval) Dualine two-line grease and oil systems in heavy industry.
Indus Hydraulics is an authorised Bijur Delimon distributor for the Middle East and supplies genuine units direct from the manufacturer, with the maker's datasheets and manuals.
How it works
On the DC41 a pressure switch in each main line actuates the FR20 reversing valve and stops the pump when system pressure reaches its setting, alternating the two lines. Stations come with 100 lb or 200 lb reservoirs, with or without a motor; the DC40 gearbox is listed separately.
Range
26 listed part numbers — systems Dualine; lubricants Grease, Oil; reservoirs 200 LB, 100 LB, 30 GAL; supply 230/460VAC; maximum pressure 3,000 psi (207 bar). The size table gives each part number's data.
Row descriptions are Bijur Delimon's own: LS / LLS level or low-level switch, HLS high-level switch, PG pressure gauge, PS pressure switch, CNTL controller, P&M pump and motor, SLR single-line resistance, PDI positive-displacement injector, PROG progressive. The columns give each part number's published data.
Where it is used
- bar mills, billet mills and blast furnaces
- sinter plants and coke ovens
- large crushers and kilns
Choosing the pump
Start from the distribution system the pump has to drive — SLR meter units, PDI injectors, progressive dividers, Dualine valves or direct multi-line feeds — then the lubricant: oil grade in cSt, or grease NLGI class (fluid grease for PDI). Size the reservoir for the refill interval you want, match the supply voltage and enclosure to the machine, and decide how the cycle is controlled: an integral timer or controller, an external controller, or the machine PLC. Level and pressure switches let the control system prove each cycle.
Complete systems
A pump is one part of a lubrication system. With it we supply the Bijur Delimon distribution — meter units, injectors, divider valves or Dualine valves — and the tubing, fittings, controllers and monitoring to match, sized to the number of points and the lubricant. Send us the machine and the lubrication points and we propose the full system.
Spare parts
Genuine Bijur Delimon service parts and kits for this range are listed by part number on Bijur Delimon Dualine Station Service Parts (DC41, DJ45 and 39900 Enclosure).
Documents
Bijur Delimon's manuals for this range are in the Downloads tab.
Identification
| Parameter | Value |
|---|---|
| Product type | Electric lubrication pump |
| Series | Bijur Delimon DC4, DC40, DC41 and DC42 Dualine Central Stations |
| Drive | Electric motor |
Application
| Parameter | Value |
|---|---|
| Lubrication system | Dualine |
| Lubricant | Grease, Oil |
| Viscosity / NLGI range | Up to NLGI #2, ISO VG 32 OR HIGHER |
Performance
| Parameter | Value |
|---|---|
| Reservoir | 200 LB, 100 LB, 30 GAL |
| Max pressure | 3,000 psi (207 bar) |
Electrical
| Parameter | Value |
|---|---|
| Supply voltage | 230/460VAC |
| Monitoring | low- and high-level switches, pressure gauge |
Connections
| Parameter | Value |
|---|---|
| Outlet thread | 1/2NPT, 3/8NPSF |
| Fill connection | QD PLUG ISO 7241-1B |
Ordering
| Parameter | Value |
|---|---|
| Supply | Genuine Bijur Delimon, direct from the manufacturer (authorised distributor) |
Shipping & lead time
Sizes & part numbers
26 sizes- Indus part no.IH-BD-37485
- Description
- 37485 — CENTRAL STATION, 200# RES STL.
- System
- —
- Lubricant
- —
- Reservoir
- —
- Supply
- —
- Max pressure
- —
- Outlet
- —
- Monitoring
- —
- Indus part no.IH-BD-LD10646
- Description
- LD10646 — DC CENTRAL STATION SUB ASSY
- System
- —
- Lubricant
- —
- Reservoir
- —
- Supply
- —
- Max pressure
- —
- Outlet
- —
- Monitoring
- —
- Indus part no.IH-BD-LD10646-M
- Description
- LD10646-M — CENTRAL STATION W/MOTR SUBASSY
- System
- —
- Lubricant
- —
- Reservoir
- —
- Supply
- —
- Max pressure
- —
- Outlet
- —
- Monitoring
- —
- Indus part no.IH-BD-DC40M32C
- Description
- DC40M32C — CENTRAL STATION 200# RES W/
- System
- —
- Lubricant
- —
- Reservoir
- —
- Supply
- —
- Max pressure
- —
- Outlet
- —
- Monitoring
- —
- Indus part no.IH-BD-DC40M32CB
- Description
- DC40M32CB — CENTRAL STATION 200# RES W/
- System
- —
- Lubricant
- —
- Reservoir
- —
- Supply
- —
- Max pressure
- —
- Outlet
- —
- Monitoring
- —
- Indus part no.IH-BD-RED13243B
- Description
- RED13243B — GEAR BOX-DC40 SERIES STATIONS
- System
- —
- Lubricant
- —
- Reservoir
- —
- Supply
- —
- Max pressure
- —
- Outlet
- —
- Monitoring
- —
- Indus part no.IH-BD-DC4131C
- Description
- DC4131C — STATION D.L. 100 LB
- System
- —
- Lubricant
- —
- Reservoir
- —
- Supply
- —
- Max pressure
- —
- Outlet
- —
- Monitoring
- —
- Indus part no.IH-BD-DC4132A
- Description
- DC4132A — DC41 100LB DUALINE NO-MTR
- System
- Dualine
- Lubricant
- Grease Up to NLGI #2
- Reservoir
- 200 LB
- Supply
- 230/460VAC, 3 ph, 50/60 Hz
- Max pressure
- 3000 psi (207 bar)
- Outlet
- 1/2NPT
- Monitoring
- low- and high-level switches, pressure gauge
Show all 26 sizesShow fewer sizes
- Indus part no.IH-BD-DC4132C
- Description
- DC4132C — DC41 200LB DUALINE LS HLS NO-MTR
- System
- Dualine
- Lubricant
- Grease Up to NLGI #2
- Reservoir
- 200 LB
- Supply
- 230/460VAC, 3 ph, 50/60 Hz
- Max pressure
- 3000 psi (207 bar)
- Outlet
- 1/2NPT
- Monitoring
- low- and high-level switches, pressure gauge
- Indus part no.IH-BD-DC41M31C
- Description
- DC41M31C — DC41 100LB DUALINE LS HLS
- System
- Dualine
- Lubricant
- Grease Up to NLGI #2
- Reservoir
- 100 LB
- Supply
- 230/460VAC, 3 ph, 50/60 Hz
- Max pressure
- 3000 psi (207 bar)
- Outlet
- 1/2NPT
- Monitoring
- pressure gauge
- Indus part no.IH-BD-DC41M31C6
- Description
- DC41M31C6 — 100# CENTRAL STATION 380 VAC
- System
- —
- Lubricant
- —
- Reservoir
- —
- Supply
- —
- Max pressure
- —
- Outlet
- —
- Monitoring
- —
- Indus part no.IH-BD-DC41M32C
- Description
- DC41M32C — DC41 200LB DUALINE LS HLS
- System
- Dualine
- Lubricant
- Grease Up to NLGI #2
- Reservoir
- 200 LB
- Supply
- 230/460VAC, 3 ph, 50/60 Hz
- Max pressure
- 3000 psi (207 bar)
- Outlet
- 1/2NPT
- Monitoring
- low- and high-level switches, pressure gauge
- Indus part no.IH-BD-DC41M32C2
- Description
- DC41M32C2 — STATION W/MOTOR NO RESERVOIR
- System
- —
- Lubricant
- —
- Reservoir
- —
- Supply
- —
- Max pressure
- —
- Outlet
- —
- Monitoring
- —
- Indus part no.IH-BD-DC41M32C4
- Description
- DC41M32C4 — STATION CENTRAL 200# 575VAC
- System
- —
- Lubricant
- —
- Reservoir
- —
- Supply
- —
- Max pressure
- —
- Outlet
- —
- Monitoring
- —
- Indus part no.IH-BD-DC41M32C6
- Description
- DC41M32C6 — CENTRAL STATION 200# RES.
- System
- —
- Lubricant
- —
- Reservoir
- —
- Supply
- —
- Max pressure
- —
- Outlet
- —
- Monitoring
- —
- Indus part no.IH-BD-DC4210211
- Description
- DC4210211 — BRACKET
- System
- —
- Lubricant
- —
- Reservoir
- —
- Supply
- —
- Max pressure
- —
- Outlet
- —
- Monitoring
- —
- Indus part no.IH-BD-DC4231C
- Description
- DC4231C — CENTRAL STATION LESS MOTOR
- System
- —
- Lubricant
- —
- Reservoir
- —
- Supply
- —
- Max pressure
- —
- Outlet
- —
- Monitoring
- —
- Indus part no.IH-BD-DC4232C
- Description
- DC4232C — DC42 200LB DUALINE LS HLS NO-MTR
- System
- Dualine
- Lubricant
- Grease Up to NLGI #2
- Reservoir
- 200 LB
- Supply
- 230/460VAC, 3 ph, 50/60 Hz
- Max pressure
- 3000 psi (207 bar)
- Outlet
- 3/8NPSF
- Monitoring
- low- and high-level switches, pressure gauge
- Indus part no.IH-BD-DC4233D
- Description
- DC4233D — DC42 30GAL DUALINE LS HLS NO-MTR
- System
- Dualine
- Lubricant
- Oil ISO VG 32 OR HIGHER
- Reservoir
- 30 GAL
- Supply
- 230/460VAC, 3 ph, 50/60 Hz
- Max pressure
- 3000 psi (207 bar)
- Outlet
- 3/8NPSF
- Monitoring
- low- and high-level switches, pressure gauge
- Indus part no.IH-BD-DC42M31A
- Description
- DC42M31A — CENTRAL STATION
- System
- —
- Lubricant
- —
- Reservoir
- —
- Supply
- —
- Max pressure
- —
- Outlet
- —
- Monitoring
- —
- Indus part no.IH-BD-DC42M31C
- Description
- DC42M31C — DC42 100LB DUALINE LS HLS
- System
- Dualine
- Lubricant
- Grease Up to NLGI #2
- Reservoir
- 100 LB
- Supply
- 230/460VAC, 3 ph, 50/60 Hz
- Max pressure
- 3000 psi (207 bar)
- Outlet
- 3/8NPSF
- Monitoring
- low- and high-level switches, pressure gauge
- Indus part no.IH-BD-DC42M32C
- Description
- DC42M32C — DC42 200LB DUALINE LS HLS
- System
- Dualine
- Lubricant
- Grease Up to NLGI #2
- Reservoir
- 200 LB
- Supply
- 230/460VAC, 3 ph, 50/60 Hz
- Max pressure
- 3000 psi (207 bar)
- Outlet
- 3/8NPSF
- Monitoring
- low- and high-level switches, pressure gauge
- Indus part no.IH-BD-DC42M32C4
- Description
- DC42M32C4 — STATION CENTRAL 200# 575VAC
- System
- —
- Lubricant
- —
- Reservoir
- —
- Supply
- —
- Max pressure
- —
- Outlet
- —
- Monitoring
- —
- Indus part no.IH-BD-DC42M32C7
- Description
- DC42M32C7 — STATION CENT 200# RES. 380VAC
- System
- —
- Lubricant
- —
- Reservoir
- —
- Supply
- —
- Max pressure
- —
- Outlet
- —
- Monitoring
- —
- Indus part no.IH-BD-DC42M33D
- Description
- DC42M33D — DC42 30GAL DUALINE LS HLS
- System
- Dualine
- Lubricant
- Oil ISO VG 32 OR HIGHER
- Reservoir
- 30 GAL
- Supply
- 230/460VAC, 3 ph, 50/60 Hz
- Max pressure
- 3000 psi (207 bar)
- Outlet
- 3/8NPSF
- Monitoring
- low- and high-level switches, pressure gauge
- Indus part no.IH-BD-DC42M33D4
- Description
- DC42M33D4 — CENTRAL STATION 30 GAL
- System
- —
- Lubricant
- —
- Reservoir
- —
- Supply
- —
- Max pressure
- —
- Outlet
- —
- Monitoring
- —
Description — What this part number is, as the manufacturer lists it. System — Lubrication system the pump feeds — SLR (single-line resistance), PDI (positive-displacement injector), progressive, Dualine or multi-line — as published. Lubricant — Oil or grease, with the viscosity or NLGI range the pump handles, as published. Reservoir — Reservoir capacity in the unit the maker publishes it. Supply — Motor or control voltage, phase and frequency, as published. Max pressure — Maximum pressure as the maker publishes it, in psi and bar. Outlet — Outlet port thread, as published. Monitoring — Level switch, pressure switch, gauge or controller the part number includes, as published.
What are Bijur Delimon DC4, DC40, DC41 and DC42 Dualine Central Stations?▾
What does an Indus part number such as IH-BD-37485 mean for Bijur Delimon DC4, DC40, DC41 and DC42 Dualine Central Stations?▾
Which part numbers and versions does Bijur Delimon DC4, DC40, DC41 and DC42 Dualine Central Stations cover?▾
How do I choose the right DC4, DC40, DC41 and DC42 Dualine Central Stations for my machine?▾
What pressure, output and reservoir ratings do Bijur Delimon DC4, DC40, DC41 and DC42 Dualine Central Stations have?▾
What is a Dualine lubrication system, and is Bijur Delimon DC4, DC40, DC41 and DC42 Dualine Central Stations used in one?▾
Which lubricants and viscosities can Bijur Delimon DC4, DC40, DC41 and DC42 Dualine Central Stations handle?▾
Which datasheets and approvals are available for Bijur Delimon DC4, DC40, DC41 and DC42 Dualine Central Stations?▾
Can Bijur Delimon DC4, DC40, DC41 and DC42 Dualine Central Stations be supplied as part of a complete lubrication system?▾
Do you supply spare parts and service kits for Bijur Delimon DC4, DC40, DC41 and DC42 Dualine Central Stations?▾
How do Bijur Delimon DC4, DC40, DC41 and DC42 Dualine Central Stations differ from Bijur Delimon CS2000 Grease Central Stations?▾
Do you keep Bijur Delimon DC4, DC40, DC41 and DC42 Dualine Central Stations in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog