Parker PTFE Fluoropolymer Tubings, Fractional

Parker PTFE Fluoropolymer Tubings, Fractional in teflon: 53 part numbers.
Product description
Parker PTFE Fluoropolymer Tubings, Fractional in teflon: 53 part numbers.
Specification
- Material: Teflon
- Working pressure stated by the maker at room temperature: 3 to 27 bar (about 45 to 390 psi), by size
- Part numbers: 53
Sizes and part numbers
The Sizes & Part Numbers tab lists every Parker part number in this range with its ratings. Ratings vary by size — check the row for the part you order.
Choosing the tubing
Select tubing on outside diameter for the push-in fittings it must fit, wall and material for pressure and temperature, and colour for circuit identification. Working pressure falls as temperature rises — check the maker rating at the operating temperature.
How to order
Quote the Parker part number. Price and lead time are confirmed with the quotation.
Specifications
| Parameter | Value |
|---|---|
| Color | Natural |
| End 1 Type | NPT |
| End 2 Type | NPT |
| Material | Teflon |
| Series | PTFE Series |
| System Of Measurement | Imperial |
Shipping & lead time
Sizes & part numbers
53 sizes- Parker Hannifin part no.101-0312031-NT-25
- I.D. (mm)
- 6.35
- Wall (mm)
- 0.79
- Description
- Parker 101 PTFE tube, 0.312" OD × 0.031" wall, natural, 25 ft
- Tube O.D. (mm)
- 7.92
- Working pressure (bar)
- 7
- Parker Hannifin part no.101-0750062-NT-100
- I.D. (mm)
- 15.88
- Wall (mm)
- 1.57
- Description
- Parker 101 PTFE tube, 0.750" OD × 0.062" wall, natural, 100 ft
- Tube O.D. (mm)
- 19.05
- Working pressure (bar)
- 6
- Parker Hannifin part no.101-0250047-NT-25
- I.D. (mm)
- 3.99
- Wall (mm)
- 1.19
- Description
- Parker 101 PTFE tube, 0.250" OD × 0.047" wall, natural, 25 ft
- Tube O.D. (mm)
- 6.35
- Working pressure (bar)
- 14
- Parker Hannifin part no.101-0250031-NT-100
- I.D. (mm)
- 4.83
- Wall (mm)
- 0.79
- Description
- Parker 101 PTFE tube, 0.250" OD × 0.031" wall, natural, 100 ft
- Tube O.D. (mm)
- 6.35
- Working pressure (bar)
- 9
- Parker Hannifin part no.101-0688062-NT-100
- I.D. (mm)
- 14.3
- Wall (mm)
- 1.57
- Description
- Parker 101 PTFE tube, 0.688" OD × 0.062" wall, natural, 100 ft
- Tube O.D. (mm)
- 17.48
- Working pressure (bar)
- 6
- Parker Hannifin part no.101-0125031-NT-25
- I.D. (mm)
- 1.57
- Wall (mm)
- 0.79
- Description
- Parker 101 PTFE tube, 0.125" OD × 0.031" wall, natural, 25 ft
- Tube O.D. (mm)
- 3.18
- Working pressure (bar)
- 20
- Parker Hannifin part no.101-0688031-NT-100
- I.D. (mm)
- 15.88
- Wall (mm)
- 0.79
- Description
- Parker 101 PTFE tube, 0.688" OD × 0.031" wall, natural, 100 ft
- Tube O.D. (mm)
- 17.48
- Working pressure (bar)
- 3
- Parker Hannifin part no.101-0500031-NT-100
- I.D. (mm)
- 11.13
- Wall (mm)
- 0.79
- Description
- Parker 101 PTFE tube, 0.500" OD × 0.031" wall, natural, 100 ft
- Tube O.D. (mm)
- 12.7
- Working pressure (bar)
- 4
Show all 53 sizesShow fewer sizes
I.D. (mm) — Inside diameter in millimetres with its tolerance, as published. Wall (mm) — Wall thickness in millimetres, as published — a single figure or a band. Description — What this part number is, as the manufacturer lists it. Tube O.D. — Outside diameter of the tube the port is cut for. Ask us for the dimension drawing if you need it stamped.
Working pressure is the manufacturer’s published rating for the fitting itself. An assembly is limited by its lowest-rated component, so check it against the hose, the tube and the port you are mating to.
What is Parker PTFE fluoropolymer tubing, fractional?▾
How do you read a Parker 101 PTFE part number such as 101-0250031-NT-100?▾
What sizes does Parker fractional PTFE tubing cover?▾
How do I choose the wall thickness for Parker fractional PTFE tubing?▾
What pressure is Parker fractional PTFE tubing rated for?▾
What chemicals can Parker PTFE fractional tubing handle?▾
What documents can be supplied with Parker fractional PTFE tubing?▾
Which fittings fit Parker 1/4" and 3/8" PTFE tubing?▾
How should Parker PTFE fractional tubing be cut and routed?▾
What is the difference between Parker fractional PTFE and Parker fractional FEP tubing?▾
What is the origin of Parker fractional PTFE tubing?▾
Do you stock Parker fractional PTFE tubing in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this range
Pneumatics & compressed air
Pneumatic tubing materials: nylon, polyurethane, polyolefin and fluoropolymer compared
Nylon holds pressure, polyurethane bends, polyolefin stays clean and fluoropolymer takes heat and chemicals — and every one of them loses pressure rating as it warms. How the four families compare on SMC’s own data, how far ratings fall with temperature, minimum bend radius, why inch and metric tube are not interchangeable, and when to specify flame-resistant, antistatic or clean-room tubing.
12 min read
Pneumatics & compressed air
Push-to-connect fittings and exhaust silencers: how they grip, seal, release and slow a cylinder
A push-in fitting grips the tube with a toothed collet and seals on its outside diameter with an O-ring — so the tube cut, the tube size and the thread end decide whether it holds. How push-in fittings work, fitting and releasing tube, pressure and temperature limits by maker, NPT vs BSPT vs BSPP, and how sintered bronze, plastic and speed-control mufflers affect exhaust back-pressure and cylinder speed.
12 min read