Parker N series, Valve Air Pilot 3 Way

Parker N series, Valve Air Pilot 3 Way: 12 part numbers.
Product description
Parker N series, Valve Air Pilot 3 Way: 12 part numbers.
Specification
- Type: Air Pilot Valve
- Pressure stated by the maker: 140 to 250 psi (10 to 17 bar), by size
- Temperature: 0°F to +125°F
- Part numbers: 12
Sizes and part numbers
The Sizes & Part Numbers tab lists every Parker part number in this range with its ratings. Ratings vary by size — check the row for the part you order.
Matching the valve
Check the valve function (2/2, 3/2, 5/2 or 5/3), port size, actuation and, for solenoid valves, the coil voltage and connector against the circuit. Quote the maker part number and we will confirm the coil and manifold options before supply.
How to order
Quote the Parker part number. Price and lead time are confirmed with the quotation.
Specifications
| Parameter | Value |
|---|---|
| Actuator/return | Air Pilot, Air Return |
| Max. Temp. | 0°F to +125°F |
| No. Of Positions | 2 |
| No. Of Ways | 3 |
| Temp. | 0°F to +125°F |
| Uses | General Pneumatics Applications |
| Vacuum | External Pilot |
Shipping & lead time
Sizes & part numbers
12 sizes- Parker Hannifin part no.N37471091
- Description
- Valve Air Pilot 3 Way 1 Inch Inlet
- Max pressure (psi)
- 140
- Parker Hannifin part no.N35431091
- Description
- Valve Air Pilot 3 Way 3/8 Inch Inlet
- Max pressure (psi)
- 250
- Parker Hannifin part no.N35441091
- Description
- Valve Air Pilot 3 Way 1/2 Inch Inlet
- Max pressure (psi)
- 250
- Parker Hannifin part no.N35461091
- Description
- Pilot Air Control Valve, 3-Way / 2-Position, 3/4 Inch Valve Port Size
- Max pressure (psi)
- 250
- Parker Hannifin part no.N35471091
- Description
- Pilot Air Control Valve, 3 Way, 1 Inch Inlet, External Pilot
- Max pressure (psi)
- 250
- Parker Hannifin part no.N36481091
- Description
- Valve Air Pilot 3 Way 1 1/4 Inch Inlet
- Max pressure (psi)
- 250
- Parker Hannifin part no.N36491091
- Description
- Valve Air Pilot 3 Way 1 1/2 Inch Inlet
- Max pressure (psi)
- 250
- Parker Hannifin part no.N37431091
- Description
- Pilot Air Control Valve, 3 Way, 3/8 Inch Inlet, External Pilot
- Max pressure (psi)
- 250
Show all 12 sizesShow fewer sizes
- Parker Hannifin part no.N37441091
- Description
- Valve Air Pilot 3 Way 1/2 Inch Inlet
- Max pressure (psi)
- 250
- Parker Hannifin part no.N37461091
- Description
- Valve Air Pilot 3 Way 3/4 Inch Inlet
- Max pressure (psi)
- 250
- Parker Hannifin part no.N38481091
- Description
- Air Pilot Valve, 3 Way, 1-1/4 Inch Inlet, 140 psi, 25 cfm
- Max pressure (psi)
- 250
- Parker Hannifin part no.N38491091
- Description
- Valve Air Pilot 3 Way 1 1/2 Inch Inlet
- Max pressure (psi)
- 250
Description — What this part number is, as the manufacturer lists it. Max pressure — Maximum (intermittent) pressure, as the manufacturer publishes it. A circuit is limited by its lowest-rated component. Ask us for the dimension drawing if you need it stamped.
Pressure, flow, speed, torque and load figures are the manufacturer’s published ratings for that part number. A circuit is limited by its lowest-rated component, so check them against the hose, fittings and valves it connects to.
What is a Parker N series 3-way air pilot valve used for?▾
How do you read Parker N series 3-way codes such as N35461091 and N37461091?▾
Which inlet sizes of the Parker N series 3-way pilot valve are available?▾
Should I choose a normally open or normally closed Parker N series 3-way valve?▾
What is the maximum pressure for a Parker N series 3-way air pilot valve?▾
Which media can a Parker N series 3-way air pilot valve handle?▾
Which certificates can come with Parker N series 3-way air pilot valves?▾
How is a Parker N series 3-way air pilot valve piped?▾
How do you check a Parker N series 3-way pilot valve in service?▾
Where are Parker N series 3-way air pilot valves used?▾
What is the origin and HS code of Parker N series 3-way air pilot valves?▾
Can I buy Parker N series 3-way air pilot valves from stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this range
Pneumatics & compressed air
Manual and air-pilot valves: hand-lever, foot-pedal, push-button, roller and pilot valves explained
How hand-lever, foot-pedal, push-button, cam and roller, and air-piloted valves work, detented vs spring-return action, how they build pneumatic logic without electricity — and why a two-hand control is a safety function under ISO 13851, not a pair of buttons.
11 min read
Pneumatics & compressed air
Solenoid valve functions explained: 3/2, 5/2 and 5/3 valves, centre conditions and port numbers
What “5/2” and “5/3 closed centre” actually mean, how to read the ISO symbol in words, normally closed vs normally open 3/2 valves, single vs double solenoid 5/2 valves, the three 5/3 centre conditions and when each one is right, direct-acting vs pilot-operated valves and the pilot pressure they need, and the port numbers 1, 2, 3, 4, 5, 12 and 14.
13 min read
Pneumatics & compressed air
Cylinder speed control: meter-out flow controls, quick exhaust valves and pilot-operated checks
Why pneumatic cylinders are normally speed-controlled meter-out, when meter-in is right, how flow controls with a bypass check work in banjo, in-line and exhaust-port forms, how a quick-exhaust valve speeds a cylinder up, and what a pilot-operated check valve can and cannot do to hold a cylinder in position on compressible air.
11 min read