Parker N series, Valve Air Pilot 2 Way

Parker N series, Valve Air Pilot 2 Way: 4 part numbers.
Product description
Parker N series, Valve Air Pilot 2 Way: 4 part numbers.
Specification
- Type: Air Pilot Valve
- Pressure stated by the maker: 250 psi (17 bar)
- Temperature: 0°F to +125°F
- Seal Material: Nitrile
- Valve Type: Poppet
- Part numbers: 4
Sizes and part numbers
The Sizes & Part Numbers tab lists every Parker part number in this range with its ratings. Ratings vary by size — check the row for the part you order.
Matching the valve
Check the valve function (2/2, 3/2, 5/2 or 5/3), port size, actuation and, for solenoid valves, the coil voltage and connector against the circuit. Quote the maker part number and we will confirm the coil and manifold options before supply.
How to order
Quote the Parker part number. Price and lead time are confirmed with the quotation.
Specifications
| Parameter | Value |
|---|---|
| Actuator Type | Remote Pilot |
| Actuator/return | Air Pilot, Air Return |
| Application | Automotive, Foundries, Pulp And Paper Mills, Steel Mills |
| Body Material | Aluminum |
| Body Style | Inline |
| Fail Position | Closed |
| Lubrication | Lubrication Not Required |
| Max. Temp. | 0°F to +125°F |
| No. Of Positions | 2 |
| No. Of Ways | 2 |
| Override | No Override |
| Product Type | Pilot Air Control Valve |
| Return Action | Pilot Return |
| Seal Material | Nitrile |
| Series | N Series |
| Temp. | 0°F to +125°F |
| Type | Normally Closed |
| Uses | General Pneumatics Applications |
| Vacuum | External Pilot |
| Valve Action | Normally Closed |
| Valve Type | Poppet |
Shipping & lead time
Sizes & part numbers
4 sizes- Parker Hannifin part no.N31431091
- Description
- Valve Air Pilot 2 Way 3/8 Inch Inlet
- Max pressure (psi)
- 250
- Ports
- 1/2", 3/8"
- Parker Hannifin part no.N31441091
- Description
- Valve Air Pilot 2 Way 1/2 Inch Inlet
- Max pressure (psi)
- 250
- Ports
- 1/2"
- Parker Hannifin part no.N31461091
- Description
- Valve Air Pilot 2 Way 3/4 Inch Inlet
- Max pressure (psi)
- 250
- Ports
- 3/4"
- Parker Hannifin part no.N31471091
- Description
- Valve Air Pilot 2 Way 1 Inch Inlet
- Max pressure (psi)
- 250
- Ports
- 1"
Description — What this part number is, as the manufacturer lists it. Max pressure — Maximum (intermittent) pressure, as the manufacturer publishes it. A circuit is limited by its lowest-rated component. Ports — Port type and size, as published. Ask us for the dimension drawing if you need it stamped.
Pressure, flow, speed, torque and load figures are the manufacturer’s published ratings for that part number. A circuit is limited by its lowest-rated component, so check them against the hose, fittings and valves it connects to.
What is a Parker N series 2-way air pilot valve used for?▾
How do Parker N series 2-way part numbers N31431091 to N31471091 show the size?▾
Which inlet sizes does the Parker N series 2-way air pilot valve come in?▾
Is the Parker N series 2-way air pilot valve normally open or normally closed?▾
What is the pressure rating of the Parker N series 2-way air pilot valve?▾
What are Parker N series 2-way pilot valves made of?▾
What documents can be supplied with Parker N series air pilot valves?▾
What pipe fittings connect to a Parker N series 2-way pilot valve?▾
How do you install a Parker N series 2-way poppet pilot valve?▾
Which industries use Parker N series 2-way air pilot valves?▾
What is the difference between Parker N series 2-way and 3-way air pilot valves?▾
Do you stock Parker N series 2-way air pilot valves in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this range
Pneumatics & compressed air
Manual and air-pilot valves: hand-lever, foot-pedal, push-button, roller and pilot valves explained
How hand-lever, foot-pedal, push-button, cam and roller, and air-piloted valves work, detented vs spring-return action, how they build pneumatic logic without electricity — and why a two-hand control is a safety function under ISO 13851, not a pair of buttons.
11 min read
Pneumatics & compressed air
Solenoid valve functions explained: 3/2, 5/2 and 5/3 valves, centre conditions and port numbers
What “5/2” and “5/3 closed centre” actually mean, how to read the ISO symbol in words, normally closed vs normally open 3/2 valves, single vs double solenoid 5/2 valves, the three 5/3 centre conditions and when each one is right, direct-acting vs pilot-operated valves and the pilot pressure they need, and the port numbers 1, 2, 3, 4, 5, 12 and 14.
13 min read
Pneumatics & compressed air
Cylinder speed control: meter-out flow controls, quick exhaust valves and pilot-operated checks
Why pneumatic cylinders are normally speed-controlled meter-out, when meter-in is right, how flow controls with a bypass check work in banjo, in-line and exhaust-port forms, how a quick-exhaust valve speeds a cylinder up, and what a pilot-operated check valve can and cannot do to hold a cylinder in position on compressible air.
11 min read