Parker 42 Series Manual/Mechanical Valves, 4-Way 3-Position

Parker 42 Series Manual/Mechanical Valves, 4-Way 3-Position: 4 part numbers.
Product description
Parker 42 Series Manual/Mechanical Valves, 4-Way 3-Position: 4 part numbers.
Specification
- Type: Manual Air Control Valve
- Pressure stated by the maker: 150 psi (10 bar)
- Temperature: 0°F to +140°F
- Part numbers: 4
Sizes and part numbers
The Sizes & Part Numbers tab lists every Parker part number in this range with its ratings. Ratings vary by size — check the row for the part you order.
Matching the valve
Check the valve function (2/2, 3/2, 5/2 or 5/3), port size, actuation and, for solenoid valves, the coil voltage and connector against the circuit. Quote the maker part number and we will confirm the coil and manifold options before supply.
How to order
Quote the Parker part number. Price and lead time are confirmed with the quotation.
Specifications
| Parameter | Value |
|---|---|
| Actuator/return | Lever, Detent |
| Body Material | Aluminum |
| Center Condition | Center Exhaust |
| Offset Return Type | Detent |
| Operator Type | Inline Perpendicular Lever |
| Pneumatic Valve Type | Inline Valve |
| Series | 42 Series |
| Valve Passages | 4 Way |
| Valve Positions | 3 Position |
Shipping & lead time
Sizes & part numbers
4 sizes- Parker Hannifin part no.422CS024W
- Description
- Manual Valve Lever 3/8 Npt 4 Way — Overall Width 1 1/4", Overall Height 5 1/2", Center Position Open
- Max pressure (psi)
- 150
- Ports
- —
- Parker Hannifin part no.422CR023W
- Description
- Manual Valve Lever 3/8 Npt 4 Way — Overall Width 2 1/4", Overall Height 5", Center Position Closed
- Max pressure (psi)
- 150
- Ports
- —
- Parker Hannifin part no.422CS023W
- Description
- Manual Valve Lever 3/8 Npt 4 Way — Overall Width 2 1/8", Overall Height 5 9/16", Center Position Closed
- Max pressure (psi)
- 150
- Ports
- 3/8"
- Parker Hannifin part no.422CR024W
- Description
- Manual Valve Lever 3/8 Npt 4 Way — Overall Width 2 1/8", Overall Height 5 1/16", Center Position Exhaust
- Max pressure (psi)
- 150
- Ports
- 3/8"
Description — What this part number is, as the manufacturer lists it. Max pressure — Maximum (intermittent) pressure, as the manufacturer publishes it. A circuit is limited by its lowest-rated component. Ports — Port type and size, as published. Ask us for the dimension drawing if you need it stamped.
Pressure, flow, speed, torque and load figures are the manufacturer’s published ratings for that part number. A circuit is limited by its lowest-rated component, so check them against the hose, fittings and valves it connects to.
What is a Parker 42 Series 4-way, 3-position lever valve used for?▾
What do the 023W and 024W endings on Parker 42 Series lever valves mean?▾
What are the overall dimensions of Parker 42 Series 4-way, 3-position valves?▾
Should I choose a closed-centre or exhaust-centre Parker 42 Series valve?▾
What pressure and temperature can a Parker 42 Series 4-way, 3-position valve handle?▾
What material is the Parker 42 Series 4-way, 3-position valve body?▾
What certificates are available for Parker 42 Series 4-way, 3-position valves?▾
How is a Parker 42 Series 3-position valve connected to a cylinder?▾
How do you test a Parker 42 Series closed-centre valve after installation?▾
How does the Parker 42 Series 4-way 3-position valve compare with the 2-position version?▾
What is the country of origin of Parker 42 Series 4-way, 3-position valves?▾
Can Parker 42 Series 4-way, 3-position valves be supplied from stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this range
Pneumatics & compressed air
Manual and air-pilot valves: hand-lever, foot-pedal, push-button, roller and pilot valves explained
How hand-lever, foot-pedal, push-button, cam and roller, and air-piloted valves work, detented vs spring-return action, how they build pneumatic logic without electricity — and why a two-hand control is a safety function under ISO 13851, not a pair of buttons.
11 min read
Pneumatics & compressed air
Solenoid valve functions explained: 3/2, 5/2 and 5/3 valves, centre conditions and port numbers
What “5/2” and “5/3 closed centre” actually mean, how to read the ISO symbol in words, normally closed vs normally open 3/2 valves, single vs double solenoid 5/2 valves, the three 5/3 centre conditions and when each one is right, direct-acting vs pilot-operated valves and the pilot pressure they need, and the port numbers 1, 2, 3, 4, 5, 12 and 14.
13 min read
Pneumatics & compressed air
Cylinder speed control: meter-out flow controls, quick exhaust valves and pilot-operated checks
Why pneumatic cylinders are normally speed-controlled meter-out, when meter-in is right, how flow controls with a bypass check work in banjo, in-line and exhaust-port forms, how a quick-exhaust valve speeds a cylinder up, and what a pilot-operated check valve can and cannot do to hold a cylinder in position on compressible air.
11 min read