Extruded Aluminium Fin Tubes

Aluminium fins extruded out of a thick aluminium sleeve over a steel, stainless or copper-alloy liner tube. Made to API 661 / ISO 13706, ASTM A179 / ASME SA179, SA334 Gr 6, ASME SA210. Supplied from Dubai with an Indus part number for each size and mill test certificates on request.
Key features
- Product type: Extruded Aluminium Fin Tubes
- Standards: API 661 / ISO 13706, ASTM A179 / ASME SA179, SA334 Gr 6, ASME SA210
- Base tube material: Carbon steel SA179, SA334 Gr 6; Stainless, duplex, titanium, copper alloys (liner of almost any material)
- Fin material: Aluminium 1100; Aluminium 1050/1060
- Outside diameter: 25.4 mm
- Fin geometry: height 9.8–16; thickness 0.3–0.65 (common 0.3/0.35/0.4); density 5–12 FPI (197–472 fins/m); 10 FPI (394 fins/m) typical
- Maximum service temperature: 285 °C typical maker limit (published 280–315 °C)
- Product type
- Extruded Aluminium Fin Tubes
- Base tube material
- Carbon steel SA179, SA334 Gr 6; Stainless, duplex, titanium, copper alloys (liner of almost any material)
- Fin material
- Aluminium 1100; Aluminium 1050/1060
Product description
Aluminium fins extruded out of a thick aluminium sleeve over a steel, stainless or copper-alloy liner tube. The sleeve covers the liner completely and leaves no crevice at the fin root, so extruded fins are the usual choice for air coolers in coastal, offshore and humid Gulf plants.
Specification
- Maximum service temperature: 285 °C typical maker limit (published 280–315 °C)
- Base tube OD (mm): 12.7–50.8 (1/2–2 in); 25.4 (1 in) most common in ACHE
- Standard base ODs (in): 1, 1 1/4, 1 1/2
- Base (liner) tube wall, carbon steel (mm): 2.11 (14 BWG) minimum per API 661
- Fin OD (mm): 38.1–76.2 (1 1/2–3 in)
- Fin height (mm): 9.8–16
- Fin thickness (mm): 0.3–0.65 (common 0.3/0.35/0.4)
- Fin density: 5–12 FPI (197–472 fins/m); 10 FPI (394 fins/m) typical
- Fin material: Aluminium 1100 (also 1050/1060)
- Max length (m): 15–18
- Atmospheric corrosion resistance: High: sleeve covers the liner tube, so no crevice at the fin root
Standards
API 661 / ISO 13706, ASTM A179 / ASME SA179, SA334 Gr 6, ASME SA210. Equivalent grades across ASTM, EN, DIN, JIS and GB/T standards are indicative; we check them against each tender.
Materials
- Tube: Carbon steel SA179, SA334 Gr 6; Stainless, duplex, titanium, copper alloys (liner of almost any material)
- Fins: Aluminium 1100; Aluminium 1050/1060
Testing and documents
- Fin bond: HTRI found bond resistance is not negligible even on new tubes
- Liner tube hydrostatic/NDT per its base spec (A179/A334)
- Mill test certificate to EN 10204 3.1 on request; third-party inspection can be arranged against your inspection and test plan
Where it is used
- Air-cooled heat exchangers in gas processing, LNG (MR and propane coolers), gas compression stations and refineries
- Coastal and offshore air coolers, where extruded fins are preferred for atmospheric corrosion
Sizes
2 sizes, each under its own Indus part number in the size table. The table lists typical sizes for the range; other sizes are made on request.
Ordering
Quote the Indus part number from the size table, or send the standard and grade, the outside diameter and wall (BWG or millimetres, minimum or average wall), the length and the quantity, with the fin type, material, height, thickness and fins per inch, and the bare length at each end. We quote with the mill certificates and the inspection you need.
Identification
| Parameter | Value |
|---|---|
| Product type | Extruded Aluminium Fin Tubes |
Compliance
| Parameter | Value |
|---|---|
| Standards | API 661 / ISO 13706, ASTM A179 / ASME SA179, SA334 Gr 6, ASME SA210 |
Construction
| Parameter | Value |
|---|---|
| Base tube material | Carbon steel SA179, SA334 Gr 6; Stainless, duplex, titanium, copper alloys (liner of almost any material) |
| Fin material | Aluminium 1100; Aluminium 1050/1060 |
Dimensions
| Parameter | Value |
|---|---|
| Outside diameter | 25.4 mm |
| Fin geometry | height 9.8–16; thickness 0.3–0.65 (common 0.3/0.35/0.4); density 5–12 FPI (197–472 fins/m); 10 FPI (394 fins/m) typical |
| Length | 15–18 m maximum single length |
| Size table | Typical sizes — other sizes on request |
Performance
| Parameter | Value |
|---|---|
| Maximum service temperature | 285 °C typical maker limit (published 280–315 °C) |
Quality
| Parameter | Value |
|---|---|
| Testing | Fin bond: HTRI found bond resistance is not negligible even on new tubes; Liner tube hydrostatic/NDT per its base spec (A179/A334) |
| Certification | Mill test certificate to EN 10204 3.1 on request; third-party inspection by arrangement |
Application
| Parameter | Value |
|---|---|
| Typical services | Air-cooled heat exchangers in gas processing, LNG (MR and propane coolers), gas compression stations and refineries; Coastal and offshore air coolers, where extruded fins are preferred for atmospheric corrosion |
Shipping & lead time
Sizes & part numbers
2 sizes- Indus part no.IH-TF-EX-ALU-0254
- O.D. (mm)
- 25.4
- O.D. (in)
- 1
- Wall (mm)
- 2.11 (14 BWG)
- Fin O.D. (mm)
- 57.15
- Fin height (mm)
- 15.88
- Fin thickness (mm)
- 0.4
- Fins per inch
- 10
- Max. length (m)
- 18
- Indus part no.IH-TF-EX-ALU-0254-B
- O.D. (mm)
- 25.4
- O.D. (in)
- 1
- Wall (mm)
- 2.11 (14 BWG)
- Fin O.D. (mm)
- 50.8
- Fin height (mm)
- 12.7
- Fin thickness (mm)
- 0.4
- Fins per inch
- 10
- Max. length (m)
- 18
O.D. (mm) — Outside diameter of the tube or pipe in millimetres. O.D. (in) — The same outside diameter in inches, as the trade orders it. Wall (mm) — Wall thickness in millimetres: minimum or average wall per the governing standard and the order. Fin O.D. (mm) — Outside diameter over the fins in millimetres. Fin height (mm) — Height of the fin above the tube surface in millimetres. Fin thickness (mm) — Fin strip or plate thickness in millimetres. Fins per inch — Fin density in fins per inch; a band means any density in it can be made. Max. length (m) — Longest single length usually made, in metres; longer on request.
These are typical sizes for the range, not a full mill list. Other diameters, walls, fin geometries and lengths are made to order: tell us the standard and grade, the O.D. and wall, and the length you need. Mill test certificates to EN 10204 3.1 are available on request.
What are Extruded Aluminium Fin Tubes used for?▾
What sizes do Extruded Aluminium Fin Tubes come in?▾
What do I need to send to order Extruded Aluminium Fin Tubes to the right size and grade?▾
What is the maximum service temperature of Extruded Aluminium Fin Tubes?▾
What tests and certificates come with Extruded Aluminium Fin Tubes?▾
Which materials and grades are Extruded Aluminium Fin Tubes available in?▾
Which standards apply to Extruded Aluminium Fin Tubes?▾
What do Extruded Aluminium Fin Tubes connect to or fit with?▾
How should Extruded Aluminium Fin Tubes be inspected on receipt and stored?▾
Where are Extruded Aluminium Fin Tubes used?▾
How are Extruded Aluminium Fin Tubes shipped, and can they be exported from Dubai?▾
Do you keep Extruded Aluminium Fin Tubes in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this part
Heat-transfer tubes
Extruded fin tube for coastal and offshore air coolers
Extruded aluminium fins cover the liner tube completely, which is why they are the usual choice for air coolers near the sea, offshore and in LNG and gas plants. How extruded tube is made, its limits, liner choices and sizes.
3 min read
Heat-transfer tubes
Finned tube fouling and cleaning in Gulf dust
Dust, sand and salt clog air-cooler fins across the Gulf every summer, just when the coolers are working hardest. How fouling builds up on finned tube, how to clean it without flattening the fins, and the design choices that make the next bundle easier to keep clean.
2 min read
Heat-transfer tubes
Finned and seamless heat-transfer tube: a buyer’s guide
How to specify tube for air coolers, shell-and-tube exchangers, condensers, boilers and fired heaters: the standard and grade, OD and wall, length, fin type and bend schedule — and what to send with an enquiry so the quotation matches the data sheet.
6 min read