Copper Tubes

Phosphorus-deoxidised copper tube (C12200, Cu-DHP) for plumbing, HVAC, refrigeration and condensers: ASTM B88 water tube in Types K, L and M, ASTM B280 ACR tube, and B111 and EN 12451 heat-exchanger tube. Made to ASTM B111, ASTM B75, ASTM B68. Supplied from Dubai with an Indus part number for each size and mill test certificates on request.
Key features
- Product type: Copper Tubes
- Construction: Seamless drawn
- Standards: ASTM B111, ASTM B75, ASTM B68, ASTM B88, ASTM B280, EN 1057, EN 12451, EN 12735-1/-2, BS 2871, IS 2501
- Base tube material: C12200 / CW024A Cu-DHP; C12000 Cu-DLP; C10200 Cu-OF; C11000 Cu-ETP (not for brazed or hydrogen service; not in B111)
- Outside diameter: 9.53–92.08 mm
- Wall thickness: 0.64–2.54 mm
- Product type
- Copper Tubes
- Construction
- Seamless drawn
- Base tube material
- C12200 / CW024A Cu-DHP; C12000 Cu-DLP; C10200 Cu-OF; C11000 Cu-ETP (not for brazed or hydrogen service; not in B111)
Product description
Phosphorus-deoxidised copper tube (C12200, Cu-DHP) for plumbing, HVAC, refrigeration and condensers: ASTM B88 water tube in Types K, L and M, ASTM B280 ACR tube, and B111 and EN 12451 heat-exchanger tube.
Specification
- C12200 chemistry: Cu ≥99.9, P 0.015–0.040
- C12000 chemistry: Cu ≥99.90, P 0.004–0.012
- C10200 chemistry: Cu ≥99.95, O ≤10 ppm
- B111 tempers for copper: H55 light-drawn, H80 hard-drawn, HE80 hard-drawn end-annealed
- B111 tensile / yield min (MPa): H55 250/205; H80 310/275
- EN 12451 Cu-DHP: R250: Rm 250, Rp0.2 150, A 20%; R290: 290/250/5%
- B88 colour code / lengths: K green, L blue, M red; straight 20 ft; K and L coils 60 ft and 100 ft (1/4–1 in)
- ACR colour / lengths: Blue; straight 20 ft (3/8–4-1/8 in); annealed coils 50 ft (1/8–1-5/8 in)
Standards
ASTM B111, ASTM B75, ASTM B68, ASTM B88, ASTM B280, EN 1057, EN 12451, EN 12735-1/-2, BS 2871, IS 2501, JIS H 3300. Equivalent grades across ASTM, EN, DIN, JIS and GB/T standards are indicative; we check them against each tender.
Materials
- Tube: C12200 / CW024A Cu-DHP; C12000 Cu-DLP; C10200 Cu-OF; C11000 Cu-ETP (not for brazed or hydrogen service; not in B111)
Testing and documents
- Eddy current per E243
- Expansion 20% (H55), 30% annealed ends (HE80)
- Mill test certificate to EN 10204 3.1 on request; third-party inspection can be arranged against your inspection and test plan
Where it is used
- HVAC and refrigeration piping, medical gas, potable water and fire services
Sizes
37 sizes, each under its own Indus part number in the size table. These are the common sizes; others are made on request.
Ordering
Quote the Indus part number from the size table, or send the standard and grade, the outside diameter and wall (BWG or millimetres, minimum or average wall), the length and the quantity. We quote with the mill certificates and the inspection you need.
Identification
| Parameter | Value |
|---|---|
| Product type | Copper Tubes |
| Construction | Seamless drawn |
Compliance
| Parameter | Value |
|---|---|
| Standards | ASTM B111, ASTM B75, ASTM B68, ASTM B88, ASTM B280, EN 1057, EN 12451, EN 12735-1/-2, BS 2871, IS 2501 |
Construction
| Parameter | Value |
|---|---|
| Base tube material | C12200 / CW024A Cu-DHP; C12000 Cu-DLP; C10200 Cu-OF; C11000 Cu-ETP (not for brazed or hydrogen service; not in B111) |
Dimensions
| Parameter | Value |
|---|---|
| Outside diameter | 9.53–92.08 mm |
| Wall thickness | 0.64–2.54 mm |
| Length | Random or fixed lengths; cut to length on request |
| Size table | Common sizes |
Quality
| Parameter | Value |
|---|---|
| Testing | Eddy current per E243; Expansion 20% (H55), 30% annealed ends (HE80) |
| Certification | Mill test certificate to EN 10204 3.1 on request; third-party inspection by arrangement |
Application
| Parameter | Value |
|---|---|
| Typical services | HVAC and refrigeration piping, medical gas, potable water and fire services |
Shipping & lead time
Sizes & part numbers
37 sizes- Indus part no.IH-TF-CU-DHP-0095-089
- Type
- Type K (B88), 1/4 in nominal
- O.D. (mm)
- 9.53
- O.D. (in)
- 0.375
- Wall (mm)
- 0.89
- Wall (in)
- 0.035
- Indus part no.IH-TF-CU-DHP-0127-124
- Type
- Type K (B88), 3/8 in nominal
- O.D. (mm)
- 12.70
- O.D. (in)
- 0.500
- Wall (mm)
- 1.24
- Wall (in)
- 0.049
- Indus part no.IH-TF-CU-DHP-0159-124
- Type
- Type K (B88), 1/2 in nominal
- O.D. (mm)
- 15.88
- O.D. (in)
- 0.625
- Wall (mm)
- 1.24
- Wall (in)
- 0.049
- Indus part no.IH-TF-CU-DHP-0190-124
- Type
- Type K (B88), 5/8 in nominal
- O.D. (mm)
- 19.05
- O.D. (in)
- 0.750
- Wall (mm)
- 1.24
- Wall (in)
- 0.049
- Indus part no.IH-TF-CU-DHP-0222-165
- Type
- Type K (B88), 3/4 in nominal
- O.D. (mm)
- 22.23
- O.D. (in)
- 0.875
- Wall (mm)
- 1.65
- Wall (in)
- 0.065
- Indus part no.IH-TF-CU-DHP-0286-165
- Type
- Type K (B88), 1 in nominal
- O.D. (mm)
- 28.58
- O.D. (in)
- 1.125
- Wall (mm)
- 1.65
- Wall (in)
- 0.065
- Indus part no.IH-TF-CU-DHP-0349-165
- Type
- Type K (B88), 1-1/4 in nominal
- O.D. (mm)
- 34.93
- O.D. (in)
- 1.375
- Wall (mm)
- 1.65
- Wall (in)
- 0.065
- Indus part no.IH-TF-CU-DHP-0413-183
- Type
- Type K (B88), 1-1/2 in nominal
- O.D. (mm)
- 41.28
- O.D. (in)
- 1.625
- Wall (mm)
- 1.83
- Wall (in)
- 0.072
Show all 37 sizesShow fewer sizes
- Indus part no.IH-TF-CU-DHP-0540-211
- Type
- Type K (B88), 2 in nominal
- O.D. (mm)
- 53.98
- O.D. (in)
- 2.125
- Wall (mm)
- 2.11
- Wall (in)
- 0.083
- Indus part no.IH-TF-CU-DHP-0095-076
- Type
- Type L (B88), 1/4 in nominal
- O.D. (mm)
- 9.53
- O.D. (in)
- 0.375
- Wall (mm)
- 0.76
- Wall (in)
- 0.030
- Indus part no.IH-TF-CU-DHP-0127-089
- Type
- Type L (B88), 3/8 in nominal
- O.D. (mm)
- 12.70
- O.D. (in)
- 0.500
- Wall (mm)
- 0.89
- Wall (in)
- 0.035
- Indus part no.IH-TF-CU-DHP-0159-102
- Type
- Type L (B88), 1/2 in nominal
- O.D. (mm)
- 15.88
- O.D. (in)
- 0.625
- Wall (mm)
- 1.02
- Wall (in)
- 0.040
- Indus part no.IH-TF-CU-DHP-0190-107
- Type
- Type L (B88), 5/8 in nominal
- O.D. (mm)
- 19.05
- O.D. (in)
- 0.750
- Wall (mm)
- 1.07
- Wall (in)
- 0.042
- Indus part no.IH-TF-CU-DHP-0222-114
- Type
- Type L (B88), 3/4 in nominal
- O.D. (mm)
- 22.23
- O.D. (in)
- 0.875
- Wall (mm)
- 1.14
- Wall (in)
- 0.045
- Indus part no.IH-TF-CU-DHP-0286-127
- Type
- Type L (B88), 1 in nominal
- O.D. (mm)
- 28.58
- O.D. (in)
- 1.125
- Wall (mm)
- 1.27
- Wall (in)
- 0.050
- Indus part no.IH-TF-CU-DHP-0349-140
- Type
- Type L (B88), 1-1/4 in nominal
- O.D. (mm)
- 34.93
- O.D. (in)
- 1.375
- Wall (mm)
- 1.40
- Wall (in)
- 0.055
- Indus part no.IH-TF-CU-DHP-0413-152
- Type
- Type L (B88), 1-1/2 in nominal
- O.D. (mm)
- 41.28
- O.D. (in)
- 1.625
- Wall (mm)
- 1.52
- Wall (in)
- 0.060
- Indus part no.IH-TF-CU-DHP-0540-178
- Type
- Type L (B88), 2 in nominal
- O.D. (mm)
- 53.98
- O.D. (in)
- 2.125
- Wall (mm)
- 1.78
- Wall (in)
- 0.070
- Indus part no.IH-TF-CU-DHP-0127-064
- Type
- Type M (B88), 3/8 in nominal
- O.D. (mm)
- 12.70
- O.D. (in)
- 0.500
- Wall (mm)
- 0.64
- Wall (in)
- 0.025
- Indus part no.IH-TF-CU-DHP-0159-071
- Type
- Type M (B88), 1/2 in nominal
- O.D. (mm)
- 15.88
- O.D. (in)
- 0.625
- Wall (mm)
- 0.71
- Wall (in)
- 0.028
- Indus part no.IH-TF-CU-DHP-0222-081
- Type
- Type M (B88), 3/4 in nominal
- O.D. (mm)
- 22.23
- O.D. (in)
- 0.875
- Wall (mm)
- 0.81
- Wall (in)
- 0.032
- Indus part no.IH-TF-CU-DHP-0286-089
- Type
- Type M (B88), 1 in nominal
- O.D. (mm)
- 28.58
- O.D. (in)
- 1.125
- Wall (mm)
- 0.89
- Wall (in)
- 0.035
- Indus part no.IH-TF-CU-DHP-0349-107
- Type
- Type M (B88), 1-1/4 in nominal
- O.D. (mm)
- 34.93
- O.D. (in)
- 1.375
- Wall (mm)
- 1.07
- Wall (in)
- 0.042
- Indus part no.IH-TF-CU-DHP-0413-124
- Type
- Type M (B88), 1-1/2 in nominal
- O.D. (mm)
- 41.28
- O.D. (in)
- 1.625
- Wall (mm)
- 1.24
- Wall (in)
- 0.049
- Indus part no.IH-TF-CU-DHP-0540-147
- Type
- Type M (B88), 2 in nominal
- O.D. (mm)
- 53.98
- O.D. (in)
- 2.125
- Wall (mm)
- 1.47
- Wall (in)
- 0.058
- Indus part no.IH-TF-CU-DHP-0095-076-B
- Type
- ACR drawn straight (B280), 3/8 in nominal
- O.D. (mm)
- 9.53
- O.D. (in)
- 0.375
- Wall (mm)
- 0.76
- Wall (in)
- 0.030
- Indus part no.IH-TF-CU-DHP-0127-089-B
- Type
- ACR drawn straight (B280), 1/2 in nominal
- O.D. (mm)
- 12.70
- O.D. (in)
- 0.500
- Wall (mm)
- 0.89
- Wall (in)
- 0.035
- Indus part no.IH-TF-CU-DHP-0159-102-B
- Type
- ACR drawn straight (B280), 5/8 in nominal
- O.D. (mm)
- 15.88
- O.D. (in)
- 0.625
- Wall (mm)
- 1.02
- Wall (in)
- 0.040
- Indus part no.IH-TF-CU-DHP-0190-107-B
- Type
- ACR drawn straight (B280), 3/4 in nominal
- O.D. (mm)
- 19.05
- O.D. (in)
- 0.750
- Wall (mm)
- 1.07
- Wall (in)
- 0.042
- Indus part no.IH-TF-CU-DHP-0222-114-B
- Type
- ACR drawn straight (B280), 7/8 in nominal
- O.D. (mm)
- 22.23
- O.D. (in)
- 0.875
- Wall (mm)
- 1.14
- Wall (in)
- 0.045
- Indus part no.IH-TF-CU-DHP-0286-127-B
- Type
- ACR drawn straight (B280), 1-1/8 in nominal
- O.D. (mm)
- 28.58
- O.D. (in)
- 1.125
- Wall (mm)
- 1.27
- Wall (in)
- 0.050
- Indus part no.IH-TF-CU-DHP-0349-140-B
- Type
- ACR drawn straight (B280), 1-3/8 in nominal
- O.D. (mm)
- 34.93
- O.D. (in)
- 1.375
- Wall (mm)
- 1.40
- Wall (in)
- 0.055
- Indus part no.IH-TF-CU-DHP-0413-152-B
- Type
- ACR drawn straight (B280), 1-5/8 in nominal
- O.D. (mm)
- 41.28
- O.D. (in)
- 1.625
- Wall (mm)
- 1.52
- Wall (in)
- 0.060
- Indus part no.IH-TF-CU-DHP-0540-178-B
- Type
- ACR drawn straight (B280), 2-1/8 in nominal
- O.D. (mm)
- 53.98
- O.D. (in)
- 2.125
- Wall (mm)
- 1.78
- Wall (in)
- 0.070
- Indus part no.IH-TF-CU-DHP-0667-203
- Type
- ACR drawn straight (B280), 2-5/8 in nominal
- O.D. (mm)
- 66.68
- O.D. (in)
- 2.625
- Wall (mm)
- 2.03
- Wall (in)
- 0.080
- Indus part no.IH-TF-CU-DHP-0794-229
- Type
- ACR drawn straight (B280), 3-1/8 in nominal
- O.D. (mm)
- 79.38
- O.D. (in)
- 3.125
- Wall (mm)
- 2.29
- Wall (in)
- 0.090
- Indus part no.IH-TF-CU-DHP-0921-254
- Type
- ACR drawn straight (B280), 3-5/8 in nominal
- O.D. (mm)
- 92.08
- O.D. (in)
- 3.625
- Wall (mm)
- 2.54
- Wall (in)
- 0.100
Type — Product or standard type of this row, where one listing covers several. O.D. (mm) — Outside diameter of the tube or pipe in millimetres. O.D. (in) — The same outside diameter in inches, as the trade orders it. Wall (mm) — Wall thickness in millimetres: minimum or average wall per the governing standard and the order. Wall (in) — The same wall thickness in inches.
These are typical sizes for the range, not a full mill list. Other diameters, walls, fin geometries and lengths are made to order: tell us the standard and grade, the O.D. and wall, and the length you need. Mill test certificates to EN 10204 3.1 are available on request.
What are Copper Tubes used for?▾
How do I read an Indus part number for Copper Tubes, such as IH-TF-CU-DHP-0095-089?▾
What sizes do Copper Tubes come in?▾
What do I need to send to order Copper Tubes to the right size and grade?▾
Which tempers are Copper Tubes supplied in?▾
Which materials and grades are Copper Tubes available in?▾
Which standards apply to Copper Tubes?▾
What do Copper Tubes connect to or fit with?▾
How should Copper Tubes be inspected on receipt and stored?▾
How do Copper Tubes differ from Plastic-Coated Copper Tubes?▾
How are Copper Tubes shipped, and can they be exported from Dubai?▾
Do you keep Copper Tubes in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations