Conrader CLS Series Inline Check Valves

Conrader CLS Series Inline Check Valves, 9 SCFM: 5 part numbers.
Product description
Conrader CLS Series Inline Check Valves, 9 SCFM: 5 part numbers.
Specification
- Type: Check Valve
- Size range: 9 SCFM
- Pressure stated by the maker: 250 psi (17 bar)
- Part numbers: 5
Sizes and part numbers
The Sizes & Part Numbers tab lists every Conrader part number in this range with its ratings. Ratings vary by size — check the row for the part you order.
Matching the valve
Check the valve function (2/2, 3/2, 5/2 or 5/3), port size, actuation and, for solenoid valves, the coil voltage and connector against the circuit. Quote the maker part number and we will confirm the coil and manifold options before supply.
How to order
Quote the Conrader part number. Price and lead time are confirmed with the quotation.
Shipping & lead time
Sizes & part numbers
5 sizes- Conrader part no.CLS1414
- Description
- Check Valve, 1/4 Inch MNPT, 250 psi Max. Pressure
- Max pressure (psi)
- 250
- Ports
- 1/4" MNPT
- Conrader part no.CLSF1414
- Description
- Check Valve, 1/4 Inch FNPT, 1/4 Inch MNPT, 250 psi Max. Pressure
- Max pressure (psi)
- —
- Ports
- —
- Conrader part no.CLS3838
- Description
- Inline Check Valve, 3/8 Inch Inlet MNPT, 3/8 Inch Outlet MNPT, 9 SCFM
- Max pressure (psi)
- —
- Ports
- —
- Conrader part no.CLS1412
- Description
- Inline Check Valve, 1/4 Inch Inlet MNPT, 1/2 Inch Outlet MNPT, 9 SCFM
- Max pressure (psi)
- —
- Ports
- —
- Conrader part no.CLS3812
- Description
- Inline Check Valve, 3/8 Inch Inlet MNPT, 1/2 Inch Outlet MNPT, 9 SCFM
- Max pressure (psi)
- —
- Ports
- —
Description — What this part number is, as the manufacturer lists it. Max pressure — Maximum (intermittent) pressure, as the manufacturer publishes it. A circuit is limited by its lowest-rated component. Ports — Port type and size, as published. Ask us for the dimension drawing if you need it stamped.
Pressure, flow, speed, torque and load figures are the manufacturer’s published ratings for that part number. A circuit is limited by its lowest-rated component, so check them against the hose, fittings and valves it connects to.
What is the Conrader CLS series inline check valve used for?▾
What do Conrader CLS series inline check valve part numbers such as CLS3838 mean?▾
What sizes does the Conrader CLS series inline check valve come in?▾
How do I choose the right Conrader CLS series inline check valve?▾
What pressure and temperature rating does the Conrader CLS series inline check valve have?▾
What is the Conrader CLS series inline check valve made of?▾
Does the Conrader CLS series inline check valve come with certificates?▾
What connects to the Conrader CLS series inline check valve?▾
How do you install the Conrader CLS series inline check valve?▾
How does the Conrader CLS series inline check valve differ from its sibling listings?▾
Where is the Conrader CLS series inline check valve made and which HS code applies?▾
Do you stock the Conrader CLS series inline check valve in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this range
Pneumatics & compressed air
Cylinder speed control: meter-out flow controls, quick exhaust valves and pilot-operated checks
Why pneumatic cylinders are normally speed-controlled meter-out, when meter-in is right, how flow controls with a bypass check work in banjo, in-line and exhaust-port forms, how a quick-exhaust valve speeds a cylinder up, and what a pilot-operated check valve can and cannot do to hold a cylinder in position on compressible air.
11 min read
Pneumatics & compressed air
Pneumatic cylinder cushioning and mounting: kinetic energy limits, side load, alignment couplers and buckling
How adjustable air cushions and bumpers stop a piston, the kinetic energy limits SMC and Parker publish and how to check against them, which mounting styles side-load a cylinder, why a flexible rod coupler matters, and how buckling limits stroke — with the makers’ own figures and rules.