Vickers Fixed Displacement Double Vane Pumps

Vickers Fixed Displacement Double Vane Pumps: 53 part numbers.
Product description
Vickers Fixed Displacement Double Vane Pumps: 53 part numbers.
Specification
- Material: Cast Iron
- Pressure stated by the maker: 2,495 to 3,046 psi (172 to 210 bar), by size
- Seal Material: Buna N
- Part numbers: 53
Sizes and part numbers
The Sizes & Part Numbers tab lists every Vickers part number in this range with its ratings. Ratings vary by size — check the row for the part you order.
Matching pump and circuit
Check flow, pressure and shaft or mounting against the machine before ordering. For tooling pumps, match the pump to the cylinder action (single- or double-acting) and the oil volume the cylinders need.
How to order
Quote the Vickers part number. Price and lead time are confirmed with the quotation.
Specifications
| Parameter | Value |
|---|---|
| Application | Oil, Gas, Metal Cutting, Dump Truck, Wheel Loader, Plastic Injection Molding |
| Material | Cast Iron |
| Seal Material | Buna N |
| Series | VHO Series |
Shipping & lead time
Sizes & part numbers
53 sizes- Vickers part no.02-137191-3
- Description
- VICKERS 02-137191-3
- Max pressure (psi)
- —
- Rated flow (GPM)
- 121.233
- Vickers part no.02-137201-1
- Description
- VICKERS 02-137201-1
- Max pressure (psi)
- —
- Rated flow (GPM)
- 121.233
- Vickers part no.02-137272-3
- Description
- VICKERS 02-137272-3
- Max pressure (psi)
- —
- Rated flow (GPM)
- 121.233
- Vickers part no.02-137323-3
- Description
- VICKERS 02-137323-3
- Max pressure (psi)
- —
- Rated flow (GPM)
- 121.233
- Vickers part no.02-137328-1
- Description
- VICKERS 02-137328-1
- Max pressure (psi)
- —
- Rated flow (GPM)
- 121.233
- Vickers part no.02-137366-1
- Description
- VICKERS 02-137366-1
- Max pressure (psi)
- —
- Rated flow (GPM)
- 121.233
- Vickers part no.02-137432-1
- Description
- VICKERS 02-137432-1
- Max pressure (psi)
- —
- Rated flow (GPM)
- 121.233
- Vickers part no.02-137440-1
- Description
- VICKERS 02-137440-1
- Max pressure (psi)
- —
- Rated flow (GPM)
- 121.233
Show all 53 sizesShow fewer sizes
Description — What this part number is, as the manufacturer lists it. Max pressure — Maximum (intermittent) pressure, as the manufacturer publishes it. A circuit is limited by its lowest-rated component. Rated flow — Rated flow in US gallons per minute, as the manufacturer publishes it. A circuit is limited by its lowest-rated component. Ask us for the dimension drawing if you need it stamped.
Pressure, flow, speed, torque and load figures are the manufacturer’s published ratings for that part number. A circuit is limited by its lowest-rated component, so check them against the hose, fittings and valves it connects to.
What are Vickers fixed displacement double vane pumps used for?▾
How are the 53 Vickers double vane pump part numbers laid out?▾
What pressure are Vickers fixed displacement double vane pumps rated for?▾
Which series are the Vickers fixed displacement double vane pumps?▾
What material and seals do Vickers double vane pumps have?▾
Which fluids suit Vickers fixed displacement double vane pumps?▾
Do Vickers double vane pumps come with test documents?▾
What do I need to match when replacing a Vickers double vane pump?▾
How do I install a Vickers fixed displacement double vane pump?▾
Which Vickers vane pump range covers a thru-drive arrangement?▾
How does a double vane pump differ from a Vickers single vane pump?▾
Are Vickers fixed displacement double vane pumps in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog
Written about this range
Cylinders, pumps & motors
Vane pumps explained: Vickers V10 and V20, double pumps, Denison T6 and T7, and reading the model code
Balanced vane pumps are quiet, compact and rebuilt by swapping a cartridge rather than the pump. How they work, the full Vickers V10 and V20 ring table with pressures and speeds, how to decode a V-series model number, changing rotation, double pumps, and where the Parker T6 and T7 families take over.
10 min read
Cylinders, pumps & motors
Hydraulic pump types: gear, vane and piston pumps compared, and how to choose
External gear, internal gear, vane, axial piston and radial piston pumps all move oil by trapping it and pushing it out, and they differ in pressure, noise, efficiency, dirt tolerance and price. How each one works, real ratings from pumps on the shelf, fixed versus variable displacement, and a selection guide.
10 min read
Cylinders, pumps & motors
How to size a hydraulic pump: flow, pressure, drive power and the inlet nobody checks
A pump is sized by the flow the actuators need and the power the drive can give it, and it fails most often on the suction side. The formulas in litres and gallons, worked examples for electric motors, engines and PTOs, line sizing, and the checks that decide whether a pump lasts five years or five weeks.
13 min read