Surface Safety Valve (SSV), Hydraulic, API 6A, 1-13/16" to 7-1/16"

Surface safety valves to API 6A and 6FA: slab gate with compact single-acting hydraulic actuator, 1-13/16" to 7-1/16", 2,000 to 20,000 psi, PR2F, skid-mounted, -46 °C to 180 °C.
Key features
- Valve type: Surface safety valve, hydraulic
- Construction: Slab gate with single-acting hydraulic actuator, on skid
- Design standard: API 6A, API 6FA
- Size range: 1-13/16" to 7-1/16"
- Pressure class: 2,000 to 20,000 psi working pressure
- Body material: API 6A material classes AA to HH (DD to HH for sour service)
- End connections: API 6A flanged or studded
- Operation: Single-acting hydraulic actuator, fail close
- Valve type
- Surface safety valve, hydraulic
- Design standard
- API 6A, API 6FA
- Pressure class
- 2,000 to 20,000 psi working pressure
- End connections
- API 6A flanged or studded
- Operation
- Single-acting hydraulic actuator, fail close
Product description
A fail-close gate valve that shuts the well automatically on an ESD signal, fire or loss of control pressure. Compact enough for crowded offshore platforms, frac wellheads, test trees and monobore wellheads, and supplied on a skid with its actuator.
Pressure-control and well-service equipment is the hardware between the well and everything downstream: it holds and directs well pressure while drilling, testing, stimulating and producing. Each piece is built to API 6A, 16A or 16C for its working pressure, temperature class and material class, with sour-service materials to NACE MR0175 / ISO 15156 where the well needs them.
Construction
- Slab gate, metal-to-metal bidirectional seal; dual self-tightening seat rings
- Stem backseat; packing leak-detection port
- Compact single-acting hydraulic actuator, top-mounted cylinder removable for seal changes
- Actuator relief; corrosion-treated internals
Sizes and ratings
Published range: 1-13/16" to 7-1/16", 2,000 to 20,000 psi working pressure, in api 6a material classes aa to hh (dd to hh for sour service). End connections: API 6A flanged or studded. Operation: single-acting hydraulic actuator, fail close.
Each unit is configured to the job; the general arrangement drawing and data book index come with the quotation.
Testing and documents
Hydrostatic tests to API 6A / 16A / 16C at the PSL ordered, with function tests of valves and controls, with the material certificates and the pressure-test record supplied with the equipment. Third-party inspection and extra tests are added when the order specifies them.
Supply
Surface safety valves are supplied from Dubai to projects, plants and maintenance teams across the GCC, the wider Middle East and Africa. Most are built to the order specification, so delivery depends on size, class, material and operator; standard carbon-steel sizes move fastest. We review the data sheet before quoting and flag anything that needs clarifying, such as a missing pipe schedule or an operator torque that has not been sized.
Related valves
Other safety and shutdown valves in the range, for comparison when the duty is not settled yet: HIPPS High Integrity Pressure Protection System, SIL 3.
Materials
| Parameter | Value |
|---|---|
| Body material | API 6A material classes AA to HH (DD to HH for sour service) |
| Seat and trim | PSL 2 to 4; PR2F |
Range
| Parameter | Value |
|---|---|
| Temperature range | -46 °C to 180 °C (L to X) |
| Size range | 1-13/16" to 7-1/16" |
| Pressure class | 2,000 to 20,000 psi working pressure |
Identification
| Parameter | Value |
|---|---|
| Valve type | Surface safety valve, hydraulic |
| Construction | Slab gate with single-acting hydraulic actuator, on skid |
Standards
| Parameter | Value |
|---|---|
| Design standard | API 6A, API 6FA |
| Pressure testing | Hydrostatic tests to API 6A / 16A / 16C at the PSL ordered, with function tests of valves and controls |
| Fire-safe design | API 6FA |
Construction
| Parameter | Value |
|---|---|
| End connections | API 6A flanged or studded |
| Operation | Single-acting hydraulic actuator, fail close |
Application
| Parameter | Value |
|---|---|
| Typical service | Wellheads, frac wellheads, test trees, offshore platforms |
Supply
| Parameter | Value |
|---|---|
| Supply | Built to order and supplied from Dubai with the documentation and test record |
Shipping & lead time
What is an API 6A hydraulic surface safety valve used for?▾
What do PSL 1 to 4 and PR1 or PR2 mean on an API 6A hydraulic surface safety valve?▾
What sizes and pressure ratings does the API 6A hydraulic surface safety valve come in?▾
What does PR2F mean on an API 6A surface safety valve?▾
How is the API 6A hydraulic surface safety valve tested?▾
Which material and temperature classes does the API 6A hydraulic surface safety valve offer?▾
Is the API 6A hydraulic surface safety valve to API specification, and what documents are supplied?▾
How is the API 6A hydraulic surface safety valve operated?▾
How does the actuator close a surface safety valve?▾
Surface safety valve or HIPPS: how do they differ?▾
Can the API 6A hydraulic surface safety valve be supplied from Dubai with test records?▾
Do you stock the API 6A hydraulic surface safety valve in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations
From the blog