Skip to content

Self-Contained Hydraulic Emergency Shutdown System

Wellhead Control Panels & ESD SystemsEx-stock · delivery in 3 days
Red gate valve with self-contained hydraulic emergency shutdown actuator, pump and pilot block
VIEW 01·Red gate valve with self-contained hydraulic emergency shutdown actuator, pump and pilot block

Self-contained hydraulic emergency shutdown systems: no external air or power, built-in hand pump to open, automatic, remote or manual shutdown in seconds, 3,000 psi main circuit, Ex-rated, IP65/66.

Key features

  • Valve type: Hydraulic emergency shutdown system
  • Construction: Self-contained hydraulic actuator, hand pump and pilot circuit
  • Design standard: Ex ia/e/d IIB/C T4–T6
  • Size range: Fitted to the shutdown valve specified
  • Pressure class: 3,000 psi main circuit; 145 psi pilot circuit
  • Body material: Stainless steel 304, 316 or 316L cabinet and tubing
  • End connections: Mounted on the valve
  • Operation: Hand pump to open; automatic, remote or manual trip
Valve type
Hydraulic emergency shutdown system
Design standard
Ex ia/e/d IIB/C T4–T6
Pressure class
3,000 psi main circuit; 145 psi pilot circuit
End connections
Mounted on the valve
Operation
Hand pump to open; automatic, remote or manual trip
Ships in 24h
Order before 14:00 GST · Jebel Ali
24-month warranty
Manufacturer-backed · genuine parts
Engineering support
A real applications engineer

Product description

An emergency shutdown valve package for remote or hazardous sites with no air or power. The valve is opened with a built-in hand pump and held open hydraulically; on fire, loss of power, a remote signal or manual trip, the circuit dumps and the valve shuts in seconds.

Control systems open, hold and close the valves that keep a well or a pipeline safe. They read pressure, fire and remote signals, and act in seconds, failing to the safe position when power or supply is lost.

Construction

  • No external energy needed; built-in manual hydraulic pump
  • Automatic shutdown on power failure or fire
  • Remote and manual on-site shutdown
  • Four system types for different trip logics

Sizes and ratings

Published range: Fitted to the shutdown valve specified, 3,000 psi main circuit; 145 psi pilot circuit, in stainless steel 304, 316 or 316l cabinet and tubing. End connections: Mounted on the valve. Operation: hand pump to open; automatic, remote or manual trip.

Each unit is configured to the job; the general arrangement drawing and data book index come with the quotation.

Testing and documents

Factory acceptance test of the panel or system, with function and pressure tests of every circuit, with the material certificates and the pressure-test record supplied with the equipment. Third-party inspection and extra tests are added when the order specifies them.

Supply

Hydraulic ESD systems are supplied from Dubai to projects, plants and maintenance teams across the GCC, the wider Middle East and Africa. Most are built to the order specification, so delivery depends on size, class, material and operator; standard carbon-steel sizes move fastest. We review the data sheet before quoting and flag anything that needs clarifying, such as a missing pipe schedule or an operator torque that has not been sized.

Related valves

Other control panels and shutdown systems in the range, for comparison when the duty is not settled yet: Wellhead Control Panel (WHCP), Single or Multi-Well.

Materials

ParameterValue
Body materialStainless steel 304, 316 or 316L cabinet and tubing
Seat and trimExplosion-proof, IP65 minimum

Range

ParameterValue
Temperature range-40 °C to 60 °C ambient
Size rangeFitted to the shutdown valve specified
Pressure class3,000 psi main circuit; 145 psi pilot circuit

Identification

ParameterValue
Valve typeHydraulic emergency shutdown system
ConstructionSelf-contained hydraulic actuator, hand pump and pilot circuit

Standards

ParameterValue
Design standardEx ia/e/d IIB/C T4–T6
Pressure testingFactory acceptance test of the panel or system, with function and pressure tests of every circuit

Construction

ParameterValue
End connectionsMounted on the valve
OperationHand pump to open; automatic, remote or manual trip

Application

ParameterValue
Typical serviceRemote wells, pipelines and high-risk sites

Supply

ParameterValue
SupplyBuilt to order and supplied from Dubai with the documentation and test record

Shipping & lead time

Lead TimeEx-stock from Dubai — delivered within 3 working days in the UAE. Export orders ship on the lane stated for the destination.

Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations

From the blog