Copper Coils — Pancake and Level-Wound

Soft annealed copper tube in pancake and level-wound coils to ASTM B280 and EN 12735-1, for air-conditioning and refrigeration installation and coil manufacture. Made to ASTM B280, ASTM B743, EN 12735-1. Supplied from Dubai with an Indus part number for each size and mill test certificates on request.
Key features
- Product type: Copper Coils
- Construction: Seamless drawn
- Standards: ASTM B280, ASTM B743, EN 12735-1, EN 12735-2
- Base tube material: C12200 / CW024A Cu-DHP
- Outside diameter: 3.18–41.28 mm
- Wall thickness: 0.76–1.52 mm
- Product type
- Copper Coils
- Construction
- Seamless drawn
- Base tube material
- C12200 / CW024A Cu-DHP
Product description
Soft annealed copper tube in pancake and level-wound coils to ASTM B280 and EN 12735-1, for air-conditioning and refrigeration installation and coil manufacture.
Specification
- ACR coil standard: ASTM B280 (annealed coils, C12200); EN 12735-1 annealed coils
- Level-wound coil standard: ASTM B743 cited with B280 by a US mill
- EN 12735-1 scope: OD 3–133 mm; coils annealed, straight lengths hard or half-hard; defines LWC and spiral-wound coils
- Pancake coil range: OD 4.76–22.22 mm, wall 0.30–1.20 mm, 15–100 m (≤9.52 mm), 15–50 m (to 18 mm), 15–25 m (19–22.22 mm)
- Annealed coil mechanicals: R220: Rm ≥220 MPa, A ≥40%
- Level-wound inner-groove coil, light-annealed C12200: elongation ≥40%, grain ≤0.040 mm, HR15T ≤65
Standards
ASTM B280, ASTM B743, EN 12735-1, EN 12735-2. Equivalent grades across ASTM, EN, DIN, JIS and GB/T standards are indicative; we check them against each tender.
Materials
- Tube: C12200 / CW024A Cu-DHP
Testing and documents
- Eddy current; ends capped, nitrogen-purged per maker practice (not standard-verified)
- Mill test certificate to EN 10204 3.1 on request; third-party inspection can be arranged against your inspection and test plan
Where it is used
- Split and VRF air-conditioning installation (pancake), coil and heat-exchanger production lines (LWC)
Sizes
12 sizes, each under its own Indus part number in the size table. These are the common sizes; others are made on request.
Ordering
Quote the Indus part number from the size table, or send the standard and grade, the outside diameter and wall (BWG or millimetres, minimum or average wall), the length and the quantity. We quote with the mill certificates and the inspection you need.
Identification
| Parameter | Value |
|---|---|
| Product type | Copper Coils |
| Construction | Seamless drawn |
Compliance
| Parameter | Value |
|---|---|
| Standards | ASTM B280, ASTM B743, EN 12735-1, EN 12735-2 |
Construction
| Parameter | Value |
|---|---|
| Base tube material | C12200 / CW024A Cu-DHP |
Dimensions
| Parameter | Value |
|---|---|
| Outside diameter | 3.18–41.28 mm |
| Wall thickness | 0.76–1.52 mm |
| Length | Random or fixed lengths; cut to length on request |
| Size table | Common sizes |
Quality
| Parameter | Value |
|---|---|
| Testing | Eddy current; ends capped, nitrogen-purged per maker practice (not standard-verified) |
| Certification | Mill test certificate to EN 10204 3.1 on request; third-party inspection by arrangement |
Application
| Parameter | Value |
|---|---|
| Typical services | Split and VRF air-conditioning installation (pancake), coil and heat-exchanger production lines (LWC) |
Shipping & lead time
Sizes & part numbers
12 sizes- Indus part no.IH-TF-CC-COI-0032-076
- O.D. (mm)
- 3.18
- O.D. (in)
- 1/8
- Wall (mm)
- 0.76
- Wall (in)
- 0.030
- Coil length
- 50 ft (15.24 m)
- Indus part no.IH-TF-CC-COI-0048-076
- O.D. (mm)
- 4.76
- O.D. (in)
- 3/16
- Wall (mm)
- 0.76
- Wall (in)
- 0.030
- Coil length
- 50 ft (15.24 m)
- Indus part no.IH-TF-CC-COI-0064-076
- O.D. (mm)
- 6.35
- O.D. (in)
- 1/4
- Wall (mm)
- 0.76
- Wall (in)
- 0.030
- Coil length
- 50 ft (15.24 m)
- Indus part no.IH-TF-CC-COI-0079-081
- O.D. (mm)
- 7.94
- O.D. (in)
- 5/16
- Wall (mm)
- 0.81
- Wall (in)
- 0.032
- Coil length
- 50 ft (15.24 m)
- Indus part no.IH-TF-CC-COI-0095-081
- O.D. (mm)
- 9.53
- O.D. (in)
- 3/8
- Wall (mm)
- 0.81
- Wall (in)
- 0.032
- Coil length
- 50 ft (15.24 m)
- Indus part no.IH-TF-CC-COI-0127-081
- O.D. (mm)
- 12.70
- O.D. (in)
- 1/2
- Wall (mm)
- 0.81
- Wall (in)
- 0.032
- Coil length
- 50 ft (15.24 m)
- Indus part no.IH-TF-CC-COI-0159-089
- O.D. (mm)
- 15.88
- O.D. (in)
- 5/8
- Wall (mm)
- 0.89
- Wall (in)
- 0.035
- Coil length
- 50 ft (15.24 m)
- Indus part no.IH-TF-CC-COI-0190-089
- O.D. (mm)
- 19.05
- O.D. (in)
- 3/4
- Wall (mm)
- 0.89
- Wall (in)
- 0.035
- Coil length
- 50 ft (15.24 m)
Show all 12 sizesShow fewer sizes
- Indus part no.IH-TF-CC-COI-0222-114
- O.D. (mm)
- 22.23
- O.D. (in)
- 7/8
- Wall (mm)
- 1.14
- Wall (in)
- 0.045
- Coil length
- 50 ft (15.24 m)
- Indus part no.IH-TF-CC-COI-0286-127
- O.D. (mm)
- 28.58
- O.D. (in)
- 1-1/8
- Wall (mm)
- 1.27
- Wall (in)
- 0.050
- Coil length
- 50 ft (15.24 m)
- Indus part no.IH-TF-CC-COI-0349-140
- O.D. (mm)
- 34.93
- O.D. (in)
- 1-3/8
- Wall (mm)
- 1.40
- Wall (in)
- 0.055
- Coil length
- 50 ft (15.24 m)
- Indus part no.IH-TF-CC-COI-0413-152
- O.D. (mm)
- 41.28
- O.D. (in)
- 1-5/8
- Wall (mm)
- 1.52
- Wall (in)
- 0.060
- Coil length
- 50 ft (15.24 m)
O.D. (mm) — Outside diameter of the tube or pipe in millimetres. O.D. (in) — The same outside diameter in inches, as the trade orders it. Wall (mm) — Wall thickness in millimetres: minimum or average wall per the governing standard and the order. Wall (in) — The same wall thickness in inches. Coil length — Length supplied in one coil, as published.
These are typical sizes for the range, not a full mill list. Other diameters, walls, fin geometries and lengths are made to order: tell us the standard and grade, the O.D. and wall, and the length you need. Mill test certificates to EN 10204 3.1 are available on request.
What are Copper Coils, Pancake and Level-Wound used for?▾
How do I read an Indus part number for Copper Coils, Pancake and Level-Wound, such as IH-TF-CC-COI-0032-076?▾
What sizes do Copper Coils, Pancake and Level-Wound come in?▾
What do I need to send to order Copper Coils, Pancake and Level-Wound to the right size and grade?▾
What tests and certificates come with Copper Coils, Pancake and Level-Wound?▾
Which materials and grades are Copper Coils, Pancake and Level-Wound available in?▾
Which standards apply to Copper Coils, Pancake and Level-Wound?▾
What do Copper Coils, Pancake and Level-Wound connect to or fit with?▾
How should Copper Coils, Pancake and Level-Wound be inspected on receipt and stored?▾
Where are Copper Coils, Pancake and Level-Wound used?▾
How are Copper Coils, Pancake and Level-Wound shipped, and can they be exported from Dubai?▾
Do you keep Copper Coils, Pancake and Level-Wound in stock in Dubai?▾
Shipped worldwide from our Dubai warehouse. Transit, routes and documentation for 136 destinations